Motorola Confidential Proprietary
Handset Test Commands
Level 3 Service Manual
2 - 9
Preliminary
Opcode
(Decimal)
Opcode
Mnemonic
Field Description
Table 3. Field and Parameter descriptions - continued
Field 1 0=set submode
1=get submode
Field 2 5 = GSM 1900
6 = GSM dual band GSM900/GSM1800
8 = WCDMA Region 1
10 = Automatic - Dual mode: WCDMA region 1 and GSM
dual band GSM900/GSM1800.a
18
INVM
Field 1 0 = Master Reset
1 = Master Clear
Field 1 Channel number in decimal. Valid channel numbers are:
• 1-124 (PGSM 900 MHz)
• 0, 975-1023 (EGSM 900 MHz)
• 512-885 (DCS 1800 MHz)
• 512-810 (PCS 1900 MHz)
Field 2 Reserved for future use and TDMA; set to 0.
34
RESTART
Field 1 As is
45
SET_RF_PWR Field 1 PA power level (0-19)
54
SUSPEND
Field 1 As is
Field 1 2 = Display Predefined Pattern
9 = Turn On/Off the Front Light
Field 2
(Data)
Data for 2,
000 = All pixels off (all black)
001 = All pixels on (all white)
005 = Grey scale block: 16 level, Black to white
006 = Horizontal Zebra Line
014 = Eight Color Box Pattern
Data for 9,
000 = Front Light Off
001 = Front Light On, Full Intensity
55
CP_MODE
10
LOAD_SYN
20
TST_DISP