Motorola Confidential Proprietary
Manual Test Procedures
Level 3 Service Manual
3 - 5
Preliminary
Call Origination (PCS Only)
Before beginning, one of the following test command
procedures needs to be completed.
Handset Test Command
•
Power up phone
•
Enter the following key sequence
•
Menu 0 H T C M D *
•
Enter the following test commands in the
Opcode screen
•
54 ok
SUSPEND
•
10*0*5
CPLOAD, GSM 1900
•
Power cycle phone
RadioComm Test Command
•
Connect as illustrated in figure 13
•
Power up phone
•
Start RadioComm application
•
Correctly select Settings option for USB or
serial
•
Click on AT+/mode, suspend, CP_Mode 1900,
respectfully
•
Power cycle phone
Repeat steps 1 through 10 in the ,“Call Origination
(GSM and DCS only),” section with the following modi-
fications,
•
Set PCS Signalling
•
BCH = 661
•
TCH = 512
Once PCS call processing is complete, return the phone
to its original state by performing the following proce-
dure,
Handset Test Command
•
54 ok
SUSPEND
•
10*0*10
CPLOAD, Dual mode
•
Power cycle phone
Computer Test Command (Radio Comm)
•
Click on AT+/mode, Suspend, CP_Mode 900/
1800, respectfully
•
Power cycle phone
Figure 14. RadioComm COM Port
Figure 15. Radio Comm Screen
GSM/DCS/PCS Call Processing