Motorola Confidential Proprietary
Handset Test Commands
Level 3 Service Manual
2 - 7
Preliminary
Opcode
(Decimal)
Opcode
Mnemonic
Field Description
Table 3. Field and Parameter descriptions
Field 2 55 through 64 = DTMF tones, refer to table xx for more tones
Field 1 0 = Set the volume specified
Field 2 0 = lowest, 7 = loudest
0 = PCAP loopback
6 = CODEC loopback
7 = VOCODER (speech) loopback
0 = Disable Audio loopback
1 = Enable Audio loopback
0 = stop a tone
1 = start a tone
0 = Vibrator
2 = Echo canceling
3 = Noise suppressor
0 = Disable
1 = Enable
This field is valid only for VOCODER loopback
0 = AMR 4.75
1 = AMR 5.15
2 = AMR 5.90
3 = AMR 6.70
4 = AMR 7.40
5 = AMR 7.95
6 = AMR 10.20
7 = AMR 12.20
8 = Full Rate
16 = Enhanced Full Rate
32 = Half Rate
0
AUD_TN_LST Field 1
3
AUD_CTRL
Field 1
Field 2
Field 2
5
AUD_LVL
Field 3
AUD_LPB
4
Field 1