www.miinet.com
Moore Industries-International, Inc.
- 125 -
User’s Manual
238-741-00K
May 2019
Programmable Smart HART Temperature Transmitter
THZ
3
/ TDZ
3
www.miinet.com
SECTION 8
Table 1.
THZ
3
/TDZ
3
Dual Input and Accuracy Table
-200 to 850°C
-328 to 1562°F
-100 to 650°C
-148 to 1202°F
-200 to 510°C
-328 to 950°F
-80 to 320°C
-112 to 608°F
-50 to 250°C
-58 to 482°F
0-4000 ohms
0-100%
-180 to 760°C
-292 to 1400°F
-150 to 1370°C
-238 to 2498°F
-170 to 1000°C
-274 to 1832°F
-170 to 400°C
-274 to 752°F
0 to 1760°C
32 to 3200°F
0 to 1760°C
32 to 3200°F
400 to 1820°C
752 to 3308°F
-130 to 1300°C
-202 to 2372°F
0 to 2300°C
32 to 4172°F
-50 to 1000mV
100
200
300
400
500
1000
100
200
400
500
1000
100
120
9.035
0-4000 ohms
125, 250, 500, 1k,
2k, 4k ohms
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
-240 to 960°C
-400 to 1760°F
-150 to 720°C
-238 to 1328°F
-240 to 580°C
-400 to 1076°F
-100 to 360°C
-148 to 680°F
-65 to 280°C
-85 to 536°F
0-4095 ohms
0-100%
-210 to 770°C
-346 to 1418°F
-270 to 1390°C
-454 to 2534°F
-270 to 1013°C
-454 to 1855.4°F
-270 to 407°C
-454 to 764.6°F
-50 to 1786°C
-58 to 3246.8°F
-50 to 1786°C
-58 to 3246.8°F
200 to 1836°C
392 to 3336.8°F
-270 to 1316°C
-454 to 2400.8°F
0 to 2338°C
32 to 4240.4°F
-50 to 1000mV
RTD
Direct
Resistance
Potentiometer
J
K
E
T
R
S
B
N
C
DC
Input
Type
α
Ohms
Conformance
Range
Minimum
Span
Input
Accuracy
Maximum
Range
10°C
(18°F)
10 ohms
10%
35°C
63°F
40°C
72°F
35°C
63°F
35°C
63°F
50°C
90°F
50°C
90°F
75°C
135°F
45°C
81°F
100°C
180°F
4mV
Ohms
TC
Platinum
Copper
Nickel
0.003850
0.003902
0.003916
0.00672
0.00427
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
±0.1°C
(±0.18°F)
±0.85°C
(±1.53°F)
±0.4 ohms
±0.1%
±0.25°C
(±0.45°F)
±0.3°C
(±0.54°F)
±0.2°C
(±0.36°F)
±0.25°C
(±0.45°F)
±0.55°C
(±0.99°F)
±0.55°C
(±0.99°F)
±0.75°C
(±1.35°F)
±0.4°C
(±0.72°F)
±0.8°C
(±1.44°F)
30 microvolts
Millivolts
Sensor-to-
Transmitter
Matching
Up to ±0.014°C
(±0.025°F)
system accuracy*
*High-accuracy
measurements are
achieved by using a 4-wire,
1000 ohm platinum RTD
with a span of 100°F (50°F
minimum) calibrated in our
sensor-matching calibration
bath.