www.miinet.com
Moore Industries-International, Inc.
- 119 -
User’s Manual
238-741-00K
May 2019
Programmable Smart HART Temperature Transmitter
THZ
3
/ TDZ
3
SECTION 6
Diagnostic Status
Input Error Summary
Input Warning Summary
Analog Output Status
Front End Status
UNUSED
Total Device Variable Failure. Given the quality of the contributing sensor
data and the availability flag settings, a valid DV could not be produced
Sensor 1 has failed
Sensor 2 has failed
Sensor 1 quality is LIMITED
0
1
14
2
PV
Status
Status
Status
Status
Status
Status
Status
Status
Status
Error
Error
Error
Error
Error
Error
Status
Status
Error
Error
Error
Error
Error
Status
Status
Error
Error
Error
Error
Error
Status
Status
Error
Error
Error
Error
Error
0
1
2
3
4
User Config Error Summary
Device Variable Config Error Summ.
5
6
Persistence Errors
7
Sensor 1 Corrosion Warning
Sensor 2 Corrosion Warning
Range Alarm Warning Summary
Status
Status
Status
Status
Status
Error
1
2
3
4
Sensor 1 Corrosion Error
Sensor 2 Corrosion Error
5
6
Range Alarm Error Summary
7
0
UNUSED
6-13
0-7
Sensor 2 quality is LIMITED
Primary sensor has failed, running on the
backup sensor (BACKUP 1-2, and 2-1 only)
4
5
The Backup sensor has failed, it is not possible to fail over
(BACKUP 1-2 and 2-1 only)
6
0
1
2
3
Total Device Variable Failure. Given the quality of the contributing sensor
data and the availability flag settings, a valid DV could not be produced
Sensor 1 has failed
Sensor 2 has failed
Sensor 1 quality is LIMITED
3
SV
Sensor 2 quality is LIMITED
Primary sensor has failed, running on the
backup sensor (BACKUP 1-2, and 2-1 only)
4
5
The Backup sensor has failed, it is not possible to fail over
(BACKUP 1-2 and 2-1 only)
6
0
1
2
3
Total Device Variable Failure. Given the quality of the contributing sensor
data and the availability flag settings, a valid DV could not be produced
Sensor 1 has failed
Sensor 2 has failed
Sensor 1 quality is LIMITED
4
TV
Sensor 2 quality is LIMITED
Primary sensor has failed, running on the
backup sensor (BACKUP 1-2, and 2-1 only)
4
5
The Backup sensor has failed, it is not possible to fail over
(BACKUP 1-2 and 2-1 only)
6
0
1
2
3
Total Device Variable Failure. Given the quality of the contributing sensor
data and the availability flag settings, a valid DV could not be produced
Sensor 1 has failed
Sensor 2 has failed
Sensor 1 quality is LIMITED
5
QV
Sensor 2 quality is LIMITED
Primary sensor has failed, running on the
backup sensor (BACKUP 1-2, and 2-1 only)
4
5
The Backup sensor has failed, it is not possible to fail over
(BACKUP 1-2 and 2-1 only)
6
0
1
2
3
Status
Status
Status
Status
Error
Error
Error
Range Alarm 1 Warning
Range Alarm 2 Warning
Range Alarm 3 Warning
Range Alarm 4 Warning
Range Alarm 1 Error
Range Alarm 2 Error
4
5
Range Alarm 3 Error
6
Error
Range Alarm 4 Error
7
0
1
2
3
UNUSED
Table 6.5.