ISA 1
Mounting
Rev. -, April 2019
9
Wing Unit
Window No.
Address DIP switch No.
1
2
3
4
5*
6*
A
1
ON
OFF
OFF
OFF
5 and 6
ON
only on the last
drive in the
wing unit
A
2
ON
ON
OFF
OFF
A
3
ON
ON
ON
OFF
A
4
ON
OFF
ON
OFF
B
1
OFF
ON
ON
OFF
B
2
OFF
OFF
ON
OFF
B
3
OFF
OFF
OFF
OFF
B
4
OFF
ON
OFF
OFF
Special Mode A
ON
OFF
OFF
ON
Special Mode B
OFF
OFF
OFF
ON
* The addresses "5" and "6" are only set to "ON" for the last sliding system drive connected
(irrespective of the number of sliding system drives connected). Address "5" connects Rx
and Tx internally for a RS232 connection.
Address "6" represents the bus termination resistor.
Example:
A sliding system block with four sliding elements and four sliding system drives is
mounted:
Set the address switch "1" in the DIP switch of the first sliding system drive to "ON".
Set the address switches "1" and "2" in the DIP switch of the second sliding system
drive to "ON".
Set the address switches "1", "2", and "3" in the DIP switch of the third sliding system
drive to "ON".
Set the address switches "1", "3", "5", and "6" in the DIP switch of the fourth sliding
system drive to "ON".
4.5
Setting the operating mode
Upon delivery, operating mode "1" is set
for the sliding system drives. Other
operating modes can be set by turning
the operating mode selector switch
(provided that they have been
configured).
Fig. 8
Operating mode selector
switch