ISA 1
Operation
Rev. -, April 2019
13
6
Operation
6.1
Operating modes
Depending on the control of the sliding system drive and of the operating elements con-
nected by the customer, the sliding system drive can be operated in the following operating
modes:
•
Start/stop
•
Teach-in run
•
Reference run
6.2
Start/stop
In case of start/stop, the sliding system drive moves the sliding element to the open or
closed position. If a new control signal is sent during the run, the sliding system drive stops
and, thus, also stops the movement of the sliding element.
7
Maintenance and care
The sliding system drive can be operated 8000
h in continuous operation without any
maintenance or care. After this period of maintenance-free continuous operation, or when
the sliding system drive is no longer operative, the sliding system drive must be replaced.
In compliance with the statutory requirements and directives, stationary electrical equip-
ments must be submitted to periodic inspections in accordance with the applicable elec-
trotechnical regulations. The Technical Directive for operational facilities recommends an
inspection interval of 4
years.
8
Performance data
Designation
Value
Unit
Type
ISA1
Revision
-
Operating voltage
100 to 240
VAC
Input current - full load
2.2/1.1
A (115/230 VAC)
Frequency
50 to 60
Hz
Rating
150
I
Torque limit
3
Nm
Max. duty cycle
10
min
Product lifetime
20
years