PARISON CONTROLLER
moog
Moog Italiana srl - Bergamo
MAN145-UM-D01A-EN
85
4.10 Work Extruder.
Figure 86
Work Extruder n.:
Work Extruder page n° (n° = 1 to 2).
Access:
From Main Menu 1 key
F5
(Extruder 1) or
F6
(Extruder 2).
Use:
It is possible to decide whether to use the extruder or not and which channel it should be associated to. It can
be associated to:
A thickness regulator in continuous extrusion.
A thickness regulator in time accumulation.
Accumulator.
It is possible to decide whether the extruder is driven by an analog or digital command. In case of analog command
the output voltage of a channel is the speed setpoint. In case of a digital command two digital outputs allow increase
or decrease of speed.
Extruder with analog command:
o
It is possible to calibrate the input with: 0 speed voltage, maximum speed voltage, and maximum
speed. The speed is expressed in RPM.
o
It is possible to calibrate the output with: maximum speed, voltage to reach maximum speed.
o
These setpoints can be setup: speed to be reached, rise ramp in RMP/sec., descent ramp in
RPM/sec., minimum speed, maximum speed.
Extruder with digital command:
o
You can setup the maximum time for digital output. (manual command or maximum velocity
control).
Summary of Contents for IMI220-145D001
Page 1: ...MOOG Manual IMI220 145D001 Parison Controller...
Page 25: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 25 Figure 26...
Page 45: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 45 Figure 37 UNIT mm...
Page 46: ...PARISON CONTROLLER moog 46 MAN145 UM D01A EN Moog Italiana srl Bergamo Figure 38 UNIT mm...
Page 54: ...PARISON CONTROLLER moog 54 MAN145 UM D01A EN Moog Italiana srl Bergamo...