PARISON CONTROLLER
moog
84
MAN145-UM-D01A-EN
Moog Italiana srl - Bergamo
4.9.3
Regulator parameters.
Figure 85
KP out 1:
Proportional gain. Range: 0 to 10000.
KI out 1:
Integral gain. Range: 0 to 10000.
KD out 1:
Derivative gain. Range: 0 to 10000.
Divisor:
It allows to choose the divisor of the formula. (see Setup
Head)
Dead band positive:
Value added to the output already calculated by the PID controller to eliminate the dead
band. Range: 0...+5000 mV or max value mA.
Dead band negative:
Value subtracted from the output already calculated by the PID controller to eliminate the
dead band. Range: 0...+5000 mV or max value mA.
4.9.4
Function Keys.
ACCUM.:
Enter the Accumulator page.
NEXT:
Enter the next Setup page.
MENU 1:
Go to main menu 1.