PARISON CONTROLLER
moog
Moog Italiana srl - Bergamo
MAN145-UM-D01A-EN
83
Figure 83
If this correction is
YES
is possible to chose a shift value to move the end extrusion position. If the difference
between the first value (STOP1) and the new value (STOP2) is lower than the shift value the correction is made.
The filling quota passed to the head is calculated from the new start point for a stroke equal to programmed injection
stroke.
Figure 84
Setting:
Allows to choose the parameters to plan (see Figure 18).
It is possible to indicate whether the machine user can freely change the parameters defining machine filling and
extrusion or there are any limitations. It is possible to select among:
1. Free entry of end of filling point, volume, end of extrusion point.
2. Entry of end of extrusion point and volume.
3. Entry end of filling point and end of extrusion point.
4. Entry end of filling point and volume.
Limitations on data entry are not valid for service level access.
Priority:
Allows to choose the parameter which has to be fixed in case of free setting (see Figure 18).
Filling voltage/current:
Output voltage or current to let the filling (to help the valve during the filling). During the
filling it is possible to define fixed output command.
Clamp voltage/current:
Output voltage or current when the end of extrusion is reached.
Push out delay:
Delay before starting the push out.
Summary of Contents for IMI220-145D001
Page 1: ...MOOG Manual IMI220 145D001 Parison Controller...
Page 25: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 25 Figure 26...
Page 45: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 45 Figure 37 UNIT mm...
Page 46: ...PARISON CONTROLLER moog 46 MAN145 UM D01A EN Moog Italiana srl Bergamo Figure 38 UNIT mm...
Page 54: ...PARISON CONTROLLER moog 54 MAN145 UM D01A EN Moog Italiana srl Bergamo...