2.2
General page description.
2.2.1
Colours assignment for all pages:
Green numbers
The fields that can be reached by cursor and can be changed.
Grey numbers
The fields that can
’t be reached by cursor and can’t be changed.
Blue bargraphs
Show the value of an analog output.
Yellow numbers
Show actual value.
Yellow bargraphs
Show actual value (feedback e.t.a.).
White
The texts on the screens.
2.2.2
Page Header:
Text left bottom:
Shows
the actual recipe that is
working.
Center:
Shows the page title.
Date and time of day:
Show the actual day, date and hour of the system. For adjustment go to the
Technical
level
or a
Resp.
level password.
Text right bottom:
(yellow) Shows the current level state:
Lock:
No password inserted.
Acc. Resp:
Access Responsible Level on. For changing this password enter in Technical
Level and enter in setup machine.
Acc. Tech:
Access Technical Level on. This password is fixed by Moog.
The other one shows the current number
page.
2.2.3
Page Bottom:
Bottom page: soft
key to change the
page
Alarm line:
If there are one or more
alarms on the alarms page, the alarms
are displayed at the bottom of each
page.
This line shows the last alarm and changes the back colour depending on the priority. On the left of the text the
number shows the code of the alarm displayed at the moment.
Min
and
Max:
Minimum
and
maximum
are displayed in the status line.
In the example on the left the minimum valid value is 0, while the
maximum is 5000.
Summary of Contents for IMI220-145D001
Page 1: ...MOOG Manual IMI220 145D001 Parison Controller...
Page 25: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 25 Figure 26...
Page 45: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 45 Figure 37 UNIT mm...
Page 46: ...PARISON CONTROLLER moog 46 MAN145 UM D01A EN Moog Italiana srl Bergamo Figure 38 UNIT mm...
Page 54: ...PARISON CONTROLLER moog 54 MAN145 UM D01A EN Moog Italiana srl Bergamo...