PARISON CONTROLLER
moog
106
MAN145-UM-D01A-EN
Moog Italiana srl - Bergamo
[036] Purge head 4 enable.
Active if the single Purge on the Work Head 4 Page is enable. It is active even used the Fast Access
Key on the front panel (All the Head).
[037] Master Tooling active.
Not managed.
[038] Tooling head 1 active.
Active if the single Tooling on the Work Head 1 Page is enable. It is active even used the Fast Access
Key on the front panel (All the Head).
[039] Tooling head 2 active.
Active if the single Tooling on the Work Head 2 Page is enable. It is active even used the Fast Access
Key on the front panel (All the Head).
[040] Tooling head 3 active.
Active if the single Tooling on the Work Head 3 Page is enable. It is active even used the Fast Access
Key on the front panel (All the Head).
[041] Tooling head 4 active.
Active if the single Tooling on the Work Head 4 Page is enable. It is active even used the Fast Access
Key on the front panel (All the Head).
[042] Feedback error channel 1.
Active if:
the analog input 1 is greater or equal 10000 mV and
Feedback Actuator
on Setup 1 Head 1 Page is
OFF;
the analog input 1 is greater or equal 10000 mV and
Feedback Actuator
on Setup 1 Head 1 Page is
ON and contemporarily
Show Feedback
on Work Head 1 Page is ON.
[043] Feedback error channel 2.
Active if:
the analog input 2 is greater or equal 10000 mV and
Feedback Actuator
on Setup 1 Head 2 Page is
OFF;
the analog input 2 is greater or equal 10000 mV and
Feedback Actuator
on Setup 1 Head 2 Page is
ON and contemporarily
Show Feedback
on Work Head 2 Page is ON.
[044] Feedback error channel 3.
Active if:
the analog input 3 is greater or equal 10000 mV and
Feedback Actuator
on Setup 1 Head 3 Page is
OFF;
the analog input 2 is greater or equal 10000 mV and
Feedback Actuator
on Setup 1 Head 3 Page is
ON and contemporarily
Show Feedback
on Work Head 3 Page is ON.
[045] Feedback error channel 4.
Active if:
the analog input 4 is greater or equal 10000 mV and
Feedback Actuator
on Setup 1 Head 4 Page is
OFF;
the analog input 2 is greater or equal 10000 mV and
Feedback Actuator
on Setup 1 Head 4 Page is
ON and contemporarily
Show Feedback
on Work Head 4 Page is ON.
Summary of Contents for IMI220-145D001
Page 1: ...MOOG Manual IMI220 145D001 Parison Controller...
Page 25: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 25 Figure 26...
Page 45: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 45 Figure 37 UNIT mm...
Page 46: ...PARISON CONTROLLER moog 46 MAN145 UM D01A EN Moog Italiana srl Bergamo Figure 38 UNIT mm...
Page 54: ...PARISON CONTROLLER moog 54 MAN145 UM D01A EN Moog Italiana srl Bergamo...