4.8.3
Accumulator parameters.
Figure 74
Push out time:
Active only if in Setup Accumulator Page the Time
control extrusion is ON. (yellow) Actual cycle time. (green) Cycle
time extrusion.
End of filling:
End of filling expressed in percentage.
Volume of filling:
Volume of filling expressed in percentage.
End of extrusion:
End of extrusion expressed in percentage.
Volume of filling is always equal to the difference between
End of filling
and
End of extrusion
.
Figure 75
In accordance with the
Setting
and
Priority
parameters set in the setup page, these three parameters can be
modified in the following ways:
Setting:
Free:
Priority:
End filling
- The priority parameter End filling is fixed when you change Volume of filling.
Priority:
End extrusion
- The priority parameter End extrusion is fixed while the other parameter End filling
changes when you change Volume of filling.
Setting:
End extr. / Volume
:
End filling is always fixed. It's possible to change only End extruder and Volume of filling.
Setting:
End filling / Volume
:
End extruder is always fixed. It's possible to change only End filling and Volume of filling.
Setting:
End filling / Extr.
:
Volume of filling is always fixed. It's possible to change only End extruder and End filling.
The analogical input referred to 100% (V. Full) has to be greater than the analogical input referred
to 0% (V. Empty).
Summary of Contents for IMI220-145D001
Page 1: ...MOOG Manual IMI220 145D001 Parison Controller...
Page 25: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 25 Figure 26...
Page 45: ...PARISON CONTROLLER moog Moog Italiana srl Bergamo MAN145 UM D01A EN 45 Figure 37 UNIT mm...
Page 46: ...PARISON CONTROLLER moog 46 MAN145 UM D01A EN Moog Italiana srl Bergamo Figure 38 UNIT mm...
Page 54: ...PARISON CONTROLLER moog 54 MAN145 UM D01A EN Moog Italiana srl Bergamo...