Page 22
XG0526-151109.2
I-Series Indoor Gas Fireplace
Installation
19). Replace the NG Pilot orifice with the LP Pilot orifice. If you
get the orifices mixed up, the LP orifice has a grove machined
around the diameter near the end.
22). Connect the unit to the gas and electrical supply.
23). Before concluding the conversion, make sure you leak test
the entire system and check all operational functions to ensure
that the unit is performing safely and properly.
Figure 33 Sec.4
20). Reverse steps to install pilot hood.
24). Fill out required information on LP conversion label.
Figure 34 Sec.4
25). Remove rating plate from under appliance and turn it over
to the blank side.
Figure 35 Sec.4
26). Apply sticker to blank side. Put rating plate back.
Figure 36 Sec.4
21). The minimum primary air setting is different depending on fuel
and burner. The minimum primary air is set by hand-bent tabs on
the primary air adjustment. Bend the appropriate tab down for your
fuel and burner. See specifications table or primary air adjustment
for proper tab. See image below for tab lengths. If your setting is
fully closed, bend both tabs up.
Figure 37 Sec.4
1/16 "
3/16 "