Page 17
XG0526-151109.2
I-Series Indoor Gas Fireplace
Installation
Door Installation & Removal
This appliance is supplied with a safety screen installed. The
Safety Screen is attached to the fireplace door using 4 screws,
and can be removed when necessary for outer glass cleaning.
The Fireplace Door is attached to the Firebox by way of 2 tabs
mounted to the top of the Firebox and by 2 spring loaded retainers
at the bottom underneath the Door. The Retainers at the bottom
of the unit are manipulated using a Door Tool that is supplied with
the unit. The general operation of the Door Retainers is:
Figure 10 Sec.4
Door Tool / Bottom of Door
Figure 11 Sec.4
Insert the Door Tool and slide left
Figure 12 Sec.4
The door latch released from the Door
Figure 13 Sec.4
Swing the Door away from the unit, lift over the retaining tabs
on top of the firebox. Be careful to not roll the gasket up off the glass when reinstalling
the door. Installation is the reverse of removal.
Engage door tool into door retainer. Pull door tool towards you and
push downwards, disengaging the door retainer from the door.
WARNING
When reinstalling door(s), always make sure all door
buckles are properly hooked and fully engaged.
a).
Engage the Door Tool into the Door Retainer
b).
Move the Door Tool to the left to release the Door Retainer
c).
Move the retainer downward and then back underneath
the Door
d).
Swing the Door outward from the unit and then lift the
Door up and over the top Tabs
Engage door tool into door retainer. Push door tool left, disengaging
the door retainer from the door.