Page 18
XG0526-151109.2
I-Series Indoor Gas Fireplace
Installation
Figure 14 Sec.4
Location of Door retainer tabs
Check that the door retainers are properly engaged.
If they are not the door relief system may not operate
properly. This can cause a risk of injury or improper
operation of the appliance.
LP Conversion
The 34FID-L is available in Natural Gas or Liquid Propane versions.
If you have a Natural Gas unit and would like to burn Propane
you can purchase an optional LP conversion kit and install it using
the following steps. To convert the unit to LP, the unit must be
disconnected from any gas supply, disconnected from any electrical
supply and batteries and removed from any installation cavity.
The 6 major items that need modification to convert a unit to LP
1). Variable regulator on the gas valve
2). The main burner orifice
3). The pilot burner orifice
4). Set minimum primary air tab
5). Label on the valve showing the new specifications
6). Gas fitter conversion label
Figure 15 Sec.4
LP conversion kit showing pilot orifice, main burner
orifice, LP stepper motor, zap strap and gas fitter conversion label.
Tools required
1). Torx T20 Screw Driver Bit
2). 3/8" Socket Driver
3). 5/32" Allen Key
4). Needle Nose Pliers or Small Flat Head Screw Driver
WARNING
When installing the fireplace - gas lines, fittings, accesso-
ries or any other objects cannot impede the proper
movement of the door buckles.