When the air filter needs to be changed, the entire air filter cartridge is dis-
carded and replaced by loosening the inlet and outlet ducting clamps and releas-
ing the retaining band snaps. The air filter is located in the rear engine compart-
ment. The changing of the air filter will need to be performed form the bed deck
access.
The alternator with integral rectifier and regulator and remote voltage sensor
is designed for reliable high output at all RPMs. This alternator offers high out-
put over a broad range of operating speeds. The 4884J deliver the same reliable,
heavy duty performance all Leece-Neville alternators are known for. The 4884J
features an integral regulator and rectifier for compact installations. While driv-
ing, if you notice that your tachometer is not operating, you may want to have
your alternator checked. The tachometer is wired to the stator terminal of the
alternator. Always keep a close eye on the voltmeter in the dash area.
Specifications
• The integral rectifier system utilizes 12: 50-amp diodes
mounted in multiple aluminum heat sinks for efficient heat
dissipation during high-output operation.
• Aluminum housings
• Bi-directional fan
• Front bearing: 305 cartridge type
• Enclosed brush system
• Weight 33 pounds
• Operation Ambient Temperature Range (-40º to 200ºF)
• Negative Ground Configuration
• Regulator Adjustment Range 13.6 to 15.4 Volts
• Batteries may start to gas at 14.3 Volts
• Max. Operating RPM 8,000
Chassis Information
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
E X E C U T I V E
7 • 2 5 3
AIR FILTER
- Changing
ALTERNATOR
Summary of Contents for Executive 2001
Page 1: ......
Page 6: ...E X E C U T I V E SECTION 1 WARRANTY INFORMATION...
Page 7: ......
Page 22: ...E X E C U T I V E SECTION 2 OPERATING SAFETY...
Page 23: ......
Page 46: ...E X E C U T I V E SECTION 3 APPLIANCES EQUIPMENT...
Page 47: ......
Page 106: ...E X E C U T I V E CHAPTER 4 WATER LP GAS SYSTEMS...
Page 107: ......
Page 129: ...Water LP Gas Systems EXECUTIVE 4 1 2 9 NOTES...
Page 130: ...E X E C U T I V E SECTION 5 ELECTRICAL SYSTEMS...
Page 131: ......
Page 177: ...Electrical Systems 5 1 7 7 EXECUTIVE N NO OT TE ES S...
Page 178: ...E X E C U T I V E SECTION 6 UNIT CARE MAINTENANCE...
Page 179: ......
Page 203: ...Unit Care Maintenance EXECUTIVE 6 2 0 3 NOTES...
Page 204: ...E X E C U T I V E SECTION 7 CHASSIS INFORMATION...
Page 205: ......