Electrical Systems
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
To enter programming mode:
Discontinue the AC supply (shore power or generator), then turn inverter
main switch to
OFF
. This shutdown procedure allows new information to be
permanently saved. Program changes made out of this sequence will leave new
changes in volatile memory. The previous settings will be re-established when
the main battery disconnects are turned to
OFF
, then back to
ON
.
Depress and hold the Set-Up buttons (up and down arrows) for five seconds.
The RC7 remote will beep. Release the buttons. The programming mode has
been entered when the Search Sense is displayed.
• Use the Menu buttons (up and down arrows) to scroll though available
field settings.
• Use the Settings button (arrow pointing to right) to scroll through
available settings for selected field.
To exit the programming mode momentarily:
• Depress the Set-up buttons (up and down arrows).
• Allow 20 seconds for changes to be accepted by the inverter.
• Turn the inverter main switch back to
ON
. The inverter is now ready to
use. “
Waiting for AC
” will be displayed, or if changes were made with
AC applied, one of the three states of charge will be displayed.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Search Sense:
The inverter will search for an AC load. Example: While inverting, AC loads
of varyious amperages may be applied. These loads may range from a few watts
to several amps. Search Sense is the cut-in point which the inverter will exit the
“sleep mode” and start inverting at a standard output voltage. The Defeat setting
allows the inverter to be at a constant standard output voltage. When changing
the Search Sense value, AC loads must be evaluated for proper inverter opera-
tion.
Auto LBCO:
The Automatic Low Battery Cut-off may turned on or off. These settings
allow the inverter to use available DC voltage to a set value while inverting.
Turning the LBCO
ON
stops the inverter when the battery voltage drops to 10.5
Volts DC. Turning the LBCO
OFF
stops the inverter when the battery voltage
drops to 8.5 Volts DC. This leaves the batteries discharged, but not completely
dead.
Battery Capacity:
The battery bank capacity is adjustable in Ahrs (amp hours). These settings
change charging curves and the length of time of the charging cycles. The range
is from 125 Ahrs to 1,000 Ahrs. Select the closest Amp Hour rating for the
house battery bank capacity. The auto setting will “learn” the battery bank size
by user characteristics. Example: Discharging and recharging the batteries on a
5 • 1 4 1
EXECUTIVE
Programming the
RC7
Adjustable
Field Settings
Summary of Contents for Executive 2001
Page 1: ......
Page 6: ...E X E C U T I V E SECTION 1 WARRANTY INFORMATION...
Page 7: ......
Page 22: ...E X E C U T I V E SECTION 2 OPERATING SAFETY...
Page 23: ......
Page 46: ...E X E C U T I V E SECTION 3 APPLIANCES EQUIPMENT...
Page 47: ......
Page 106: ...E X E C U T I V E CHAPTER 4 WATER LP GAS SYSTEMS...
Page 107: ......
Page 129: ...Water LP Gas Systems EXECUTIVE 4 1 2 9 NOTES...
Page 130: ...E X E C U T I V E SECTION 5 ELECTRICAL SYSTEMS...
Page 131: ......
Page 177: ...Electrical Systems 5 1 7 7 EXECUTIVE N NO OT TE ES S...
Page 178: ...E X E C U T I V E SECTION 6 UNIT CARE MAINTENANCE...
Page 179: ......
Page 203: ...Unit Care Maintenance EXECUTIVE 6 2 0 3 NOTES...
Page 204: ...E X E C U T I V E SECTION 7 CHASSIS INFORMATION...
Page 205: ......