To recalibrate LP tank gauge proceed as follows:
NOTE: Fill LP tank prior to calibration.
Using adjustment tool, simultaneously push button for tank
and rotate adjustment point. Turn counterclockwise until the
light indication is decreasing, then gently, rotate the adjustment
back clockwise until the light indication is at full.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Liquid Propane Gas is heavier than air and will settle to
the lowest point, which is generally the floor of your
motorhome. The LP-Gas detector is also sensitive to other
fumes such as hair spray, most of which contain butane as
the propellant. Butane, like propane, is heavier than air and
will settle to the floor level where it will be detected. When
this occurs, press the reset button to stop the alert sound for
60 seconds.
The other combustibles which will be detected include
alcohol, liquor, deodorants, colognes, perfumes, wine, adhe-
sives, lacquer, kerosene, gasoline, glues, most all cleaning
agents and aerosol can propellant. Most are lighter than air
in their vapor state and will only be detected when the
motorhome is closed up.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
When the power is first applied the Yellow LED will flash for three minutes
while the detector is stabilizing. At the end of that time the LED will turn Green
indicating full operation. If the detector has detected unsafe levels of gas it will
immediately go into alarm.
CAUTION: This detector cannot alarm during the three-minute warm-
up cycle.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Simply press the Test switch any time during the warm up cycle or while in nor-
mal operation. The LED should flash RED and the alarm should sound. Release the
switch. This is the only way you should test your detector. The test feature checks
the full operation of the detector.
Water & LP-Gas Systems
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
E X E C U T I V E
4 • 1 2 7
LP-GAS DETECTOR
LP Detector.
Adjustment Point
Operation
Testing
Summary of Contents for Executive 2001
Page 1: ......
Page 6: ...E X E C U T I V E SECTION 1 WARRANTY INFORMATION...
Page 7: ......
Page 22: ...E X E C U T I V E SECTION 2 OPERATING SAFETY...
Page 23: ......
Page 46: ...E X E C U T I V E SECTION 3 APPLIANCES EQUIPMENT...
Page 47: ......
Page 106: ...E X E C U T I V E CHAPTER 4 WATER LP GAS SYSTEMS...
Page 107: ......
Page 129: ...Water LP Gas Systems EXECUTIVE 4 1 2 9 NOTES...
Page 130: ...E X E C U T I V E SECTION 5 ELECTRICAL SYSTEMS...
Page 131: ......
Page 177: ...Electrical Systems 5 1 7 7 EXECUTIVE N NO OT TE ES S...
Page 178: ...E X E C U T I V E SECTION 6 UNIT CARE MAINTENANCE...
Page 179: ......
Page 203: ...Unit Care Maintenance EXECUTIVE 6 2 0 3 NOTES...
Page 204: ...E X E C U T I V E SECTION 7 CHASSIS INFORMATION...
Page 205: ......