Adjusting Camera, Lens Focus and Installing Filters
3.3.2 Adjusting Lens Focus (B119/B237 Only)
Once the camera has been installed, the B119 and B237 sensor modules should be checked
for proper image sharpness and manually adjusted, if required. To do so, use the blue lens
wrench and the black module wrench (both are supplied with the M16 basic module).
The focusing aid provides a visual aid when correcting the image sharpness (see The Live
Screen of the MOBOTIX Camera in the camera’s online help).
Procedure
1. Position the blue lens wrench on the notches of the
sensor module. Rotate the wrench
to the left
until
you feel a stop (max. 300°) and then a little bit fur-
ther until the protective glass lens slides out of the
sensor module.
2. Adjust the image sharpness according to the camera’s
live image on the computer monitor. To do so, posi-
tion the black module wrench (with the ring-pattern
side) on the lens and carefully rotate to the right or
left.
Do not turn the lens too far or with force to
avoid damaging the image sensor.
3. If required, clean the inside of the protective glass
lens using a clean, lint-free cotton cloth.
4. Place the protective glass lens on the notches of the
blue lens wrench.
5. Position the protective glass lens with its clips over
the two receptacles on the sensor module (red arrow
on the image in the margin) and firmly press onto the
sensor module. Rotate the glass
to the right
using
the blue lens wrench until you feel a stop.
6. If required, clean the outside of the protective glass lens using a clean, lint-free cot-
ton cloth.
M.6
M.7
Summary of Contents for AllroundDual M16B
Page 1: ...Camera Manual AllroundDual M16 33 068 002_EN_09 2020 ...
Page 2: ...2 M16 Camera Manual ...
Page 9: ...9 ...
Page 35: ...35 MOBOTIX Software Notes ...
Page 75: ...75 Network and Power Connection Notes ...
Page 121: ...121 Additional Notes Notes ...
Page 122: ...122 M16 Camera Manual Notes ...
Page 123: ...123 Manufacturer ...
Page 124: ...Camera Manual AllroundDual M16 ...