Initial commissioning
49
Fig.9-3: System settings,
“Layer thickness settings” menu
A/B
Distance of the sensor to the screed rear edge
(min. 100 mm, max. 9999 mm)
C/D
Distance of the sensor to the ground
Additional warning notices:
Sensor not connected
Sensor out of operating range
Fig.9-4: System settings,
“Layer thickness measurement” menu
1)
Select the appropriate menu item by turning the handwheel (2) and set the
value for the distance to the screed rear edge.
2)
Press the handwheel (1) and confirm the value.
The distances of the sensors to the ground are not adjustable! Only the value
measured from the respective sensor is displayed.