Troubleshooting
58
Operating instructions
6 Troubleshooting
6.1 Cause of failure and the remedy
Failure
Possible causes
Remedy
The control does not react
The control is defective
•
Disconnect the unit from the electric
mains.
•
Contact Customer service.
An internal fuse has tripped
•
Contact Customer service.
The "Start Stop" indicator light
flashes twice when the "Start Stop"
button is pressed
An audible signal sounds over 3
seconds
The safety temperature limiter has
tripped
•
Disconnect the unit from the electric
mains.
•
Contact Customer service.
??????
In the case of units with tilting: Pan
is not in the operating position
Bring the pan into the operating position
The unit does not heat up
Unit switched off
•
Switch on the unit.
Temperature display on "0"
•
Set the temperature.
Power supply interrupted
•
Contact the authorized technical person-
nel.
Unit defective
•
Disconnect the unit from the electric
mains.
•
Contact Customer service.
Insufficient heat output
Unit defective
•
Disconnect the unit from the electric
mains.
•
Contact Customer service.
Mains phase missing
•
Contact the authorized technical person-
nel.
The
Heating indicator light does not
illuminate
An audible signal sounds over 3
seconds
Pan tilted (unit with tilting)
•
Tilt back the pan (operating position)
Unit defective
•
Disconnect the unit from the electric
mains.
•
Contact Customer service.
The
Heating indicator light flashes
Interruption of the power
optimisation system
•
Disconnect the unit from the electric
mains.
•
Contact Customer service.
6.2 Nameplate
When contacting Customer service, please always provide the
following data from the nameplate:
Serial number
(SN)
Type number
(TYP)
2021441-20ABBE-B
Summary of Contents for O7EMPF Series
Page 6: ...Directory of contents 6 Operating instructions 2021441 20ABBE B...
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ...www mkn eu...