Form 801661B
Page Number - 5
INSTRUCTIONS FOR USE
Fluid Dispensing
1 . Unscrew the cap from the fluid transfer bottle,
and fill to desired level with clean fluid .
2 . Reinstall the cap onto the bottle and hang the
assembly in a safe, secure location within reach
of the application .
3 . Close the ball valve located on the fluid hose
assembly extending from the bottom of the
bottle .
4 . Connect the fluid dispensing wand or other ac-
cessory to the quick-change coupler on the end
of the fluid hose assembly . Ensure the coupler
sleeve snaps forward to lock the connection .
5 . Connect a Mityvac hand pressure pump w/
pressure gauge to the inlet hose extending
from the side of the fluid transfer bottle .
6 . While observing the gauge, operate the pump
to build pressure in the fluid transfer bottle to
the desired level . Do not exceed 20 psi (1 .4 bar)
pressure .
7 . Insert the fluid wand into the reservoir you wish
to fill or top-off, and open the ball valve to allow
the flow of fluid .
NOTE: Continual operation of the pump is
not required to maintain fluid flow . Fluid will
continue to flow as long as there is pressure in
the reservoir and the shutoff valve is open .
8 . Once the proper amount of fluid has been
dispensed, close the shutoff valve and release
the pressure in the system by activating the
pressure relief lever on the hand pump .
9 . Depending on the type of fluid and future
intended use, you may store the remaining fluid
in the reservoir . Otherwise empty the bottle
assembly, clean it with denatured alcohol or a
common household cleaner, and store it prop-
erly .
Fluid Evacuation
1 . Hang the fluid transfer bottle assembly in a safe,
secure location within reach of the application .
2 . Close the ball the valve located on the fluid
hose assembly extending from the bottom of
the fluid transfer bottle .
3 . Connect the fluid dispensing wand or other ac-
cessory to the quick-change coupler on the end
of the fluid hose assembly . Ensure the coupler
sleeve snaps forward to lock the connection .
4 . Connect a Mityvac hand vacuum pump to the
inlet hose extending from the side of the fluid
transfer bottle .
5 . Operate the pump to build vacuum in the
bottle .
6 . Insert the fluid wand into the reservoir from
which you intend to draw fluid, and open the
ball valve to allow the flow of fluid .
NOTE: Continual operation of the pump is
not required to maintain fluid flow . Fluid will
Hand pump
(sold separately)
Fluid dispensing wand
Brake master cylinder
TYPICAL DISPENSING/
EVACUATION APPLICATION