3. SLMP
3 - 7
3.4.4 SDO Object SubID Block Download (CiA 402 object sub ID continuous write)
When the slave stations (servo amplifiers) receive the CiA 402 object sub ID continuous write request from
the master station (external device), they write a specified value to the object corresponding to the specified
Index or consecutive Sub Index.
(1) Request message (command and the following)
Command Sub
command Index
Sub
Index
Reserved
Number of data
value
Write data
L H L H L H - - L H
L
or
H
(variable)
20h
40h
06h
00h
Refer to (3) in this section for details.
(2) Response message
(a) At normal completion (end code and the following)
End code
Index
Sub
Index
Reserved
Number of data
value
L H L H - - L H
00h
00h
Refer to (3) in this section for details.
(b) At abnormal completion
The response message is the same as that of 3.2 (2) (b).
(3) Item list
Item Size
Endian
Description
Command 2
bytes
Little
H4020
Sub command
2 bytes
Little
H0006
Index
2 bytes
Little
Specify Index of the object. (Refer to chapter 7.)
For the response message, the value specified in the request message is
stored.
Sub Index
1 bytes
Little
Specify Sub Index of the object. (Refer to chapter 7.)
For the response message, the value specified in the request message is
stored.
Reserved
1 bytes
Fixed to H00
Number of data value
2 bytes
Little
Write data: Specify the size in hexadecimal.
Write data
Variable
Little
Specify the write data of the object.
Summary of Contents for MR-JE series
Page 9: ...A 8 MEMO...
Page 21: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO...
Page 39: ...5 PARAMETERS 5 8 MEMO...
Page 45: ...6 MANUFACTURER FUNCTIONS 6 6 MEMO...
Page 89: ...7 OBJECT LIBRARY 7 44 MEMO...
Page 91: ...MEMO...