Chapter 4
50
Connecting devices
4.1.3
Enabling switch (e.g. SICK E100)
Electrical connection: Example from Setting and Monitoring Tool with WS0-XTIO
2 positions,
connected to 24 V
Channel 1: Contact E31 between 24 V and I1
Channel 2: Contact E41 between 24 V and I2
2 positions,
connected to test
output
Channel 1: Contact E31 between X1 and I3
Channel 2: Contact E41 between X2 and I4
3 positions,
connected to 24 V
Channel 1: Contact E13 between 24 V and I5
Channel 2: Contact E23 between 24 V and I6
Channel 3: Contact E31 between 24 V and I7
Channel 4: Contact E41 between 24 V and I8
3 positions,
connected to test
output
Channel 1: Contact E13 between 24 V and I1
Channel 2: Contact E23 between 24 V and I2
Channel 3: Contact E31 between X1 and I3
Channel 4: Contact E41 between X2 and I4
Function
Notes
Testing Possible
Series connection
Not possible
Discrepancy times
See Setting and Monitoring Tool.
Further information is available in the manual of the enabling switch, SICK E100 or in
the manuals of devices used.
Table 24:
Connection of enabling
switches
Table 25:
Functions of enabling
switches
Note