DISASSEMBLY PROCEDURE
PHOTOS
92
11. How to remove the pressure relief valve/manometer/air
vent (automatic)
<Pressure relief valve (3 bar)>
(3) Remove the field piping from the pressure relief valve (3
bar). (Photo 11-5)
(4) Remove the pressure relief valve (3 bar) with the flare
joint using 2 spanners: one to hold the flare joint and the
other to turn the flare nut. (Photo 11-5)
(5) Remove the pressure relief valve (3 bar) using 2
spanners: one to hold the flare joint and the other to turn
the pressure relief valve (3 bar). (Photo 11-6)
(6) Eliminate loctite on the thread surfaces using remover.
(Photo 11-6)
•
Before reinstallation, apply loctite over the thread
surface on the pressure relief valve.
•
For more details about the loctite and the remover,
refer to Page 101.
<Air vent (automatic)>
(3) Remove the air vent (automatic) using 2 spanners: one
to hold the flare joint and the other to turn the flare nut.
(Photos 11-5)
(4) Remove the air vent with the flare joint. (Photo 11-5)
(5) Remove the flare joint from the air vent. (Photo 11-7)
<Pressure relief valve (10 bar) (Except for EH*T20*-MHCW
models)>
(3) Remove the field piping from the pressure relief valve
(10 bar). (Photo 11-8)
(4) Remove the pressure relief valve (10 bar) with the flare
joint using 2 spanners: one to hold the flare joint and the
other to turn the flare nut. (Photo 11-9)
(5) Remove the pressure relief valve (10 bar) using 2
spanners: one to hold the flare joint and the other to turn
the pressure relief valve (10 bar). (Photo 11-10)
(6) Eliminate loctite on the thread surfaces using remover.
(Photo 11-10)
•
Before reinstallation, apply loctite over the thread
surface on the pressure relief valve.
•
For more details about the loctite and the remover,
refer to Page 101.
Photo 11-6
Photo 11-5
Photo 11-9
Photo 11-10
Photo 11-7
Air vent
Flare joint
Pressure relief
valve (3 bar)
Flare joint
Threads for application of loctite
From the previous page.
Photo 11-8 (Except for EH*T20*-MHCW models)
Air vent
(automatic)
Pressure relief
valve (3 bar)
Air vent
(automatic)
Pressure relief
valve (3 bar)
Pressure relief
valve (10 bar)
Flare joint
Flare nut
Pressure relief
valve (10 bar)
Flare joint
Threads for application of loctite
Flare joint
Flare nut
Flare joint
Flare nut
Pressure relief
valve (10 bar)
OCH570C