7
SPECIFICATIONS
3
Optional extras
●
Wireless Remote Controller
PAR-WT50R-E
●
Remote Sensor
PAC-SE41TS-E
*1
Volume of sanitary water circuit, primary DHW circuit (from 3-wa
y valve to confluent point with heating circuit), piping to expa
nsion vessel, and expansion vessel are not included in this val
ue.
*2
The environment must be frost-free.
*3 Cooling mode is not available in low outdoor temperature. If you use our system in cooling mode at the low ambient temperature (10°C or below), there are some risks of plate heat exchanger breaking by frozen water
.
*4 For the model without both booster heater and immersion heater
, the maximum allowable hot water temperature is [Maximum outlet water of outdoor unit −3°C]
For the maximum outlet water of outdoor unit, refer to outdoor unit data book.
*5
Tested under BS7206 conditions.
*6 Do not fit immersion heaters without thermal cut-out.
●
Wireless Receiver
PAR-WR51R-E
●
Thermistor
PAC-TH01
1-E
●
Immersion heater (1Ph 3 kW)
PAC-IH03V2-E
●
High temperature thermistor
PAC-TH01
1HT
-E
●
EHPT
Accessories for UK
PAC-WK01UK-E
●
ecodan Wi-Fi Interface
PAC-WF010-E
●
Drain pan stand
PAC-DP01-E
●
2-zone kit
PAC-TZ01-E
Model name (Service Ref.)
EHST20C- VM2C.UK
EHST20C- VM6C.UK
EHST20C- YM9C.UK
EHST20C- TM9C.UK
EHST20C- VM2EC.UK
EHST20C- VM6EC.UK
EHST20C- YM9EC.UK
EHST20C- MEC.UK
EHST20D- VM2C.UK
EHST20D- MEC.UK
EHST20D- MHC.UK
EHST20D- VM2EC.UK
EHST20D- YM9C.UK
Nominal domestic hot water volume
200L
Overall unit dimensions
1600 × 595 × 680 mm (Height × Width × Depth)
W
eight (empty)
110 kg
11
1 kg
112 kg
112 kg
104 kg
105 kg
106 kg
103 kg
103 kg
96 kg
103 kg
97 kg
105 kg
W
eight (full)
320 kg
321 kg
322 kg
322 kg
314 kg
315 kg
316 kg
313 kg
312 kg
305 kg
312 kg
306 kg
314 kg
W
ater volume of heating circuit in the unit *1
6.6 kg
6.6 kg
6.6 kg
6.6 kg
6.6 kg
6.6 kg
6.6 kg
6.6 kg
5.7 kg
5.7 kg
5.7 kg
5.7 kg
5.7 kg
Plate heat exchanger (MW
A2)
—
—
—
—
—
Plate heat exchanger (MW
A1)
—
—
—
—
—
—
—
—
Unvented expansion vessel(Primary heating)
Nominal volume
12 L
—
—
-—
—
12 L
—
12 L
—
12 L
Charge pressure
1 bar
—
—
—
—
1 bar
—
1 bar
—
1 bar
Safety device
W
ater
circuit (Primary)
Control thermistor
Heating
1–80°C
Pressure relief valve
0.3 MPa (3bar)
Flow sensor
Min. flow 5.0 L/min
Boos
ter
heater
Manual reset thermostat
90°C
—
90°C
—
—
90°C
Thermal Cut-out (for dry run prevention)
121°C
—
121°C
—
—
121°C
DHW tank
Control thermistor
40–70°C
Temperature and pressure relief valve/
Pressure relief valve
1.0 MPa (10 bar)
Primary circuit circulating Pump
Grundfos UPM2 15-70 130
Sanitary circuit circulating Pump
Grundfos UPSO 15-60 130 CIL2
Connections
W
ater
28 mm compression primary circuit/ 22 mm compression DHW circuit
Refrigerant (R410A)
Liquid
9.52 mm
6.35 mm
Gas
15.88 mm
12.7 mm
Target temperature range
Flow tem- perature
Heating
25–60°C
Cooling
—
Room tem- perature
Heating
10–30°C
Cooling
—
Guaranteed operating range
Ambient *2
0–35°C (
80 %RH)
Outdoor temperature
Heating
See outdoor unit spec table.
Cooling
—
DHW tank performance
Maximum allowable hot water temperature
70°C
*4
70°C
*4
70°C
Time to raise DHW tank temp. 15–65°C *5
22.75 min
Time to reheat 70% of DHW tank to 65°C *5
17.17 min
Electrical data
Control board
Power supply
(Phase, voltage, frequency)
~/N, 230 V
, 50 Hz
Breaker (when powered
from independent source)
10
A
Booster heater
Power supply
(Phase, voltage, frequency)
~/N, 230 V
,
50 Hz
~/N, 230 V
,
50 Hz
3~, 400 V
,
50 Hz
3~, 230 V
,
50 Hz
~/N, 230 V
,
50 Hz
~/N, 230 V
,
50 Hz
3~, 400 V
,
50 Hz
—
~/N, 230 V
,
50 Hz
—
—
~/N, 230 V
,
50 Hz
3~, 400 V
,
50 Hz
Capacity
2 kW
2 kW+4 kW
3 kW+6 kW
3 kW+6 kW
2 kW
2 kW+4 kW
3 kW+6 kW
—
2 kW
—
—
2 kW
3 kW+6 kW
Current
9 A
26
A
13
A
23
A
9 A
26
A
13
A
—
9 A
—
—
9 A
13A
Breaker
16
A
32
A
16
A
32
A
16
A
32
A
16
A
—
16
A
—
—
16
A
16
A
Immersion heater *6
Power supply
(Phase, voltage, frequency)
—
~/N, 230 V
,
50 Hz
—
Capacity
—
3 kW
—
Current
—
13
A
—
Breaker
—
16
A
—
Sound level
28dBA
OCH570C
Summary of Contents for EHPT20X-MHCW