63
DIP SWITCH FUNCTION
9
9-1. Indoor unit
DIP switch and jumper connector functions.
Each function is controlled by the jumper connector in the control p.c.board. Below table shows that the function setting by the
jumper connector is available or not in the control p.c.board of applicable units. Also J11~15 (SW1) and J21~24 (SW2) has Dip
switch with their jumper connector.
Functions and signification of the jumper connector (Dip switch)
PLA-RP • AA
PLA-RP •AA.UK
PKA -RP •GAL
PKA-RP •FAL
PCA-RP •GA
PEA-RP • EA.TH-A
PEAD-RP • EA.UK
PEAD-RP •GA.UK
J11~J15 (SW1) ; Model setting
J21~J24 (SW2) ; Capacity setting
Applicable units
: Changeable function
: Not changeable function
INDOOR CONTROLLER BOARD
type B
type A
J11~J15
(SW1)
type A
Function
Model
settings
Capacity
settings
Pair number
setting with
wireless remote
controller
type B
PLA-RP • AA
Model
J11~J15 (SW1)
J11 J12 J13 J14 J15
PCA-RP • GA
PKA-RP • GAL
PKA-RP • FAL
PEA-RP • EA
Models
J11~J15 (SW1)
J11 J12 J13 J14 J15
PEAD-RP • EA
PEAD-RP • GA
J21~J24
(SW2)
J41
J42
In above table
Jumper connector : Short, Open
Note 1: If the settings of SW1 (model settings) or SW2 (capacity settings) on the service PCB are made incorrectly:
•If the SW1 settings are made incorrectly, the unit will not operate, or won't be able to operate normally.
•The SW1 (model) and SW2 (capacity) settings are used to send the indoor unit's model and capacity
information to the outdoor unit. The outdoor unit uses this information to perform control, so the expected
performance may not be achieved if the information is incorrect.
•In models with indoor fan phase control, pulsation control or DC fan control, the SW2 (capacity) settings are
used to control the fan air volume. If the settings are made incorrectly, the air volume may be higher or lower
than expected, performance may drop, or the noise level may increase.
0
1
2
3 ~ 9
Wireless remote
controller setting
Control PCB setting
J41
J42
PLA-RP1.6AA
PLA-RP2AA
PLA-RP2.5AA
PLA-RP3AA, AA
1
PLA-RP4AA, AA
1
PLA-RP5AA
PLA-RP5AA
1
PLA-RP6AA, AA
1
PKA-RP2.5FAL
PKA-RP3FAL
PKA-RP4FAL
PEA-RP3EA
PEA-RP4EA
PEA-RP5EA
PEAD-RP1.6EA
PEAD-RP2EA
PEAD-RP2.5EA
PEAD-RP3EA,EA
1
PEAD-RP4EA,EA
1
PEAD-RP5EA,EA
1
PEAD-RP6EA,EA
1
PEAD-RP2.5GA
PEAD-RP3GA
PEAD-RP4GA
PKA-RP1.6GAL
PKA-RP2GAL
PCA-RP2GA
PCA-RP2.5GA
PCA-RP3GA
PCA-RP4GA
PCA-RP5GA
PCA-RP6GA
PLA-RP1.6AA
PLA-RP2AA
PLA-RP2.5AA
PLA-RP3AA, AA
1
PLA-RP4AA, AA
1
PLA-RP5AA
PLA-RP5AA
1
PLA-RP6AA, AA
1
PKA-RP2.5FAL
PKA-RP3FAL
PKA-RP4FAL
PEA-RP3EA
PEA-RP4EA
PEA-RP5EA
PEAD-RP1.6EA
PEAD-RP2EA
PEAD-RP2.5EA
PEAD-RP3EA,EA
1
PEAD-RP4EA,EA
1
PEAD-RP5EA,EA
1
PEAD-RP6EA,EA
1
PEAD-RP2.5GA
PEAD-RP3GA
PEAD-RP4GA
PKA-RP1.6GAL
PKA-RP2GAL
PCA-RP2GA
PCA-RP2.5GA
PCA-RP3GA
PCA-RP4GA
PCA-RP5GA
PCA-RP6GA
Models
J21~J24 (SW2)
J21 J22 J23 J24
Models
SW2
1
ON
ON
ON
ON
OFF
OFF
ON
2
ON
OFF
ON
OFF
OFF
ON
ON
3
OFF
ON
ON
OFF
ON
ON
ON
4
OFF
OFF
OFF
ON
ON
ON
ON
Service PCB
<Settings at time of factory shipment>
Wireless remote controller: 0
Control PCB: (for both J41 and J42)
Four pair number settings are supported.
The pair number settings of the wireless remote controller
and indoor control PCB (J41/J42) are given in the table on
the left. (' ' in the table indicates the jumper line is disconnected.)
OCT04A-3.qxp 04.9.29 9:16 AM Page 63