76
10
FUNCTION SETTING
PAR-20MAA
ON/OFF
CENTRALLY CONTROLLED
ERROR CODE
CLOCK
ON
OFF
˚C
CHECK
CHECK MODE
FILTER
TEST RUN
FUNCTION
˚C
1Hr.
NOT AVAILABLE
STAND BY
DEFROST
FILTER
CHECK TEST
TEMP.
TIMER SET
F
E
G
C D
A
B
12 3 4
Wired type
1
Mode number
2
Setting number
3
Refrigerant address
4
Unit number
Changing the power voltage setting
• Be sure to change the power voltage setting depending on the voltage
used.
3
Setting the unit number
Press
D
(CLOCK ON OFF) and [--] will start to flash in the unit number
(
4
) display (see diagram
3
).
Use the
C
(TIMER SET) button to set the unit number to 00
(see diagram
3
). Press to increase the value or to decrease it.
Unit number 00 = the function setting selection for the entire refrigerant
system.
00 is the typical setting. When operating in a group configuration, use
the correlating refrigerant address (see the technical manual for details
on setting the refrigerant address for a group). The refrigerant address-
es must be set in order when performing the following operation.
If the unit stops two seconds after the FUNCTION display starts to flash
or [88] starts to flash in the room temperature display, a transmission
problem may have occurred. Check to see if there is some source of
transmission interference (noise) nearby.
If you make a mistake during any point of this procedure, you can quit
the function setting mode by pressing
8
once and then return to step
1
.
*
FUNCTION
FUNCTION
1
2
3
FUNCTION
FUNCTION
3
4
[Operating instructions] (entering settings with a wired remote controller)
1
Go to the function setting mode.
Switch OFF the remote controller.
Press the
A
FILTER and
B
TEST RUN buttons simultaneously and hold
them for at least 2 seconds. FUNCTION will start to flash. The refrigerant
address display will start to flash momentarily (see diagram
1
).
2
Setting the refrigerant address
Use the
C
(TIMER SET) button to set the refrigerant address
(
3
) to 00 (see diagram
2
). Press to increase the value or
to
decrease it.
Selecting functions using the wired remote controller
1
Check the function selection setting.
2
Switch to function setting mode.
w
(Press
A
and
B
at the same time
with the remote controller stopped.)
w
For modes 15 and higher,
press
J
and
B
at the same
time.
3
Specify refrigerant address 00 (outdoor unit)
4
Specify unit No. 00. (indoor unit)
(Use
C
and
D
.)
5
Enter the setting.
(Press
E
.)
(Specified indoor unit:
BLOW operation)
Change refrigerant
address unit No.
6
Select mode No 02
(room temperature detection position).
7
Select setting No. 03 (remote controller fixed).
(Use
F
and
G
.)
9
8
Enter the setting.
(Press
E
.)
Finished
10
Function selection end screen
(Press
A
and
B
at the same time.)
YES
YES
NO
NO
Example:
Selecting room temperature
detection position