103
3
Remote controller, indoor/outdoor unit transmission error
4
M-NET transmission error (High Prior)
Error code
E0
E3
E4
E5
E6
E7
E8
E9
EA
Eb
EC
Ed
EF
No beep
No beep
Beep(one sec.) x 9
Beep(one sec.) x 9
Beep(one sec.) x 3
Beep(one sec.) x 3
Short 2 beeps (0.4 sec.) x 3
Short 2 beeps (0.4 sec.) x 3
Short 2 beeps (0.4 sec.) x 2
Short 2 beeps (0.4 sec.) x 2
Short 2 beeps (0.4 sec.) x 2
Short 2 beeps (0.4 sec.) x 4
Beep(one sec.) x 10
Short 2 beeps (0.4 sec.) x 10
No display
No display
6831
3832
6840
6841
6840
6841
6844
6845
6846
0403
6607 or 6608
Remote Controller
Remote Controller
Indoor
Indoor
Indoor
Indoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Indoor
Outdoor
P114
P114
P108
P108
P108
P108
P114
P114
P110
P110
P110
P114
P114
Remote controller transmission error (Signal receiving error)
Remote controller transmission error (Transmitting error)
Remote controller transmission error (Signal receiving error)
Remote controller transmission error (Transmitting error)
Indoor/outdoor unit transmission error (Signal receiving error)
Indoor/outdoor unit transmission error (Transmitting error)
Indoor/outdoor unit transmission error (Signal receiving error)
Indoor/outdoor unit transmission error (Transmitting error)
Start-up time over
Serial Transmission error
Not defined.
Beep output
High prior
remote controller
Unit which
detects error
Error details
Inspection
method and
troubleshooting
Display of remote
controller or A
control service tool
Mis-wiring of indoor/outdoor unit connector
(Converse wiring / Disconnection)
Mis-wiring of indoor/outdoor unit connector
The number of indoor unit is over the limit. (Limit: 4 units)
Error code
A0
A2
A3
A6
A7
A8
Short 2 beeps (0.4 sec.) x 4
Short 2 beeps (0.4 sec.) x 4
Short 2 beeps (0.4 sec.) x 4
Short 2 beeps (0.4 sec.) x 4
Short 2 beeps (0.4 sec.) x 4
Short 2 beeps (0.4 sec.) x 4
6600
6602
6603
6606
6607
6608
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
P115
P115
P115
P115
P116, P117
P118
M-NET: Address-duplicated definition
M-NET: Hardware error of transmission P line
M-NET: BUS BUSY
M-NET: Transmission error with transmission P line
M-NET: No ACK
M-NET: No RESPONSE
Beep output
High prior
remote controller
Unit which
detects error
Error details
Inspection
method and
troubleshooting
Display of remote
controller or A
control service tool
OCT04A-4.qxp 04.9.29 9:17 AM Page 103