131
SYSTEM CONTROL
15
Outdoor
unit
Indoor
unit
Remote
controller
Indoor
unit
Remote
controller
Outdoor
unit
Indoor
unit
Remote
controller
Indoor unit
Remot
controller
Relay box
Distant operating
panel
Indoor
unit
Remote
controller
Remote
display kit
Remote display panel
(Operation : Error)
Indoor
unit
Remote
controller
• There are two types of remote controllers: wired type and
wireless type.
• Simultaneous twin, triple and quad units are counted as one
unit and the indoor units can be operated or stopped simul-
taneously.
• An individual twin is counted as two units and the indoor
units can be operated independently. Each can perform a
different operation. For example, one unit can be used for
cooling while another is used for heating.
15-1. VARIETY OF SYSTEM CONTROL FUNCTIONS
A. Remote controller
operation
(Standard type)
Parts To Be Procured
(Sold separately or
obtained locally.)
Features
System Diagram
System Name
• Up to two remote controller can be connected to one group.
• Simultaneously twin, triple and quad units are counted as
one group.
• The operating control is the most recent command (last
entered priority).
B. Two remote con-
troller operation
• Wired remote con-
troller
• Wireless remote
controller
• The remote controller is connected and the address for
each outdoor unit is set so that a group of up to 16 units can
be started sequentially.
• Simultaneous twin, triple and quad units are counted as one
unit.
• One group can operate in the same mode but the on/off
operation of the thermostat is performed independently by
each outdoor unit.
C. 1 remote controller
group operation
• Wired remote con-
troller
• This can be set by using the function selection from the
remote controller.
D. Power failure auto-
matic recovery
operation
• The remote controller cord for the wired remote controller
can be extended to up to 500 meters.
w
The optical receiving section cord for the wireless remote
controller cannot be extended.
E. Individual opera-
tion from separate
room
• Remote controller
extension cord (0.3
to 1.25 mm
2
)
• Group on/off of all air conditioners can be done from remote
unit.
• Switching of remote control/hand-held control can be per-
formed.
F. Control operation of
joint remote/ hand-
held units.
• Remote ON/OFF
(PAC-SE55RA-E)
Relay box (Installed
locally)
• Compatible with either level or pulse signals.
G. Operation by
external signal
• Remote ON/OFF
(PAC-SE55RA-E)
• Connect the "Remote Operation Adapter" (sold separately)
and "Remote Display Panel" (Installed locally) to permit no-
voltage contact output of each signal for operation and error
and remote input functions (pulse input) to be added.
H. Erasing of remote
display
• Remote operation
adapter
(PAC-SF40RM-E)
• Remote Display
Panel (Installed
locally)
1
1
On/Off time can be set in increments of 10 minutes. The
standard model allows for up to one control cycle in a 24
hour period. There are three kinds of timers: on timer, off,
timer and on/off timer.
I. Timer operation
2
2
Connecting the "Program Timer" (sold separately) to the
remote controller will provide setting control for On/Off in 30
minute increments in day increments.
3
3
Connection the "Remote Operation Adapter" to the circuit
board of the indoor unit will allow operating control to be
performed by a commercially available timer
• Program timer
(PAC-SC32PTA)
• Remote Operation
Adapter
(PAC-SE55RA-E)
• Timer (Commercially
available)