2 PARAMETER SETTINGS
2.4 Refresh Settings
59
2
Refresh processing time
A refresh processing time [
s] is a constituent of the scan time of the CPU module. For details on the scan time, refer to the
following.
MELSEC iQ-R CPU Module User's Manual (Application)
The refresh processing time [
s], which is taken for refresh, is given by:
• Refresh processing time [
s] = Refresh read time (time for transferring refresh data to the CPU module) + Refresh write
time (time for transferring refresh data to the I/O module with diagnostic functions)
The refresh read time and refresh write time vary depending on the settings of "Target".
When "Target" is "Module Label" or "Refresh Data Register (RD)"
The following table shows the refresh read time and refresh write time with an R
CPU used.
When "Target" is "Device"
Calculate the refresh read time and refresh write time according to the number of items and the number of their transfer data
(in units of word) that are set to be refreshed. For the calculation method, refer to the following.
MELSEC iQ-R CPU Module User's Manual (Application)
Model
Classification
When using the refresh settings
RX40NC6B
Refresh read time
24.71
s
Refresh write time
9.69
s
RY40PT5B
Refresh read time
22.78
s