![Mitsubishi Electric FR-F500 Series Instruction Manual Download Page 159](http://html.mh-extra.com/html/mitsubishi-electric/fr-f500-series/fr-f500-series_instruction-manual_239240159.webp)
PARAMETERS
146
4.2.53 Override bias/gain (Pr. 252, Pr. 253)
Pr. 252 "override bias"
Pr. 253 "override gain"
When you have selected override in Pr. 73 "0 to 5V, 0 to 10V selection", you can increase the override range
of 50%-150% (to 0%-200%) and make setting as desired.
Parameter Number
Setting Range
Minimum Setting
Increments
Factory Setting
252
0 to 200%
0.1%
50%
253
0 to 200%
0.1%
150%
Pr.252
0V
2.5V
(5V)
5V
(10V)
0
50
100
150
200
Pr.253
Factory setting (50% to 150%)
O
v
e
rrid
e
(%
)
Voltage across terminals 2-5
Pr. 73 "0-5V/0-10V selection"
Related parameter