PARAMETERS
118
<Setting items and set data>
After completion of parameter setting, set the instruction codes and data and start communication from the
computer to allow various types of operation control and monitoring.
No.
Item
Instruction
Code
Description
Number of
Data Digits
Read
H7B
H0000: Communication option operation
H0001: External operation
H0002: Communication operation (PU connector)
1
Operation
mode
Write
HFB
H0000: Communication option operation
H0001: External operation
H0002: Communication operation (PU connector)
4 digits
Output frequency
[speed]
H6F
H0000 to HFFFF: Output frequency (hexadecimal) in 0.01Hz
increments
[Speed (hexadecimal) in r/min increments if Pr. 37 = 1 to
9998 or Pr. 144 = 2 to 10, 102 to 110.]
4 digits
Output current
H70
H0000 to HFFFF: Output current (hexadecimal) in 0.01A
increments
4 digits
Output voltage
H71
H0000 to HFFFF: Output voltage (hexadecimal) in 0.1V
increments
4 digits
Special monitor
H72
H0000 to HFFFF: Monitored data selected by instruction code
HF3
4 digits
H01 to H0E
Monitor selection data
Data
Description
Incre-
ments
Data
Description
Incre-
ments
H01
Output
frequency
0.01Hz
H0A
Electronic
overcurrent
protection load
factor
0.1%
H02
Output current
0.01A
H0B
Output current
peak value
0.01A
Read
H73
H03
Output voltage
0.1V
H0C
Converter output
voltage peak
value
0.1V
H05
Frequency
setting
0.01Hz
H0D
Input power
0.01kW
H06
Running
speed
r/min
H0E
Output power
0.01kW
H08
Converter
output voltage
0.1V
Special monitor
selection No.
Write
HF3
2 digits
H0000 to HFFFF: Two most recent alarm definitions
Read data: [Example] H30A0
Most recent alarm
(HA0)
b15
b8b7
b0
0 0 1 1 0 0
0
0
0 0 0 0 0
0
1
1
(Previous alarm ........ THT)
(Most recent alarm ..... OPT)
Previous alarm
(H30)
Alarm data
Data
Description
Data
Description
Data
Description
H00
No alarm
H50
IPF
HB0
PE
H10
0C1
H51
UVT
HB1
PUE
H11
0C2
H60
OLT
HB2
RET
H12
0C3
H80
GF
HC1
CTE
H20
0V1
H81
LF
HC2
P24
H21
0V2
H90
OHT
HF3
E. 3
H22
0V3
HA0
OPT
HF6
E. 6
H30
THT
HA1
OP1
HF7
E. 7
H31
THM
HA2
OP2
H40
FIN
HA3
OP3
2
M
oni
to
ri
ng
Alarm definition
H74 to H77
4 digits
Summary of Contents for FR-F500 Series