PARAMETERS
139
4.2.46 User group selection (Pr. 160, Pr. 173 to Pr. 176)
Pr. 160 "user group read selection"
Pr. 173 "user group 1 registration"
Pr. 174 "user group 1 deletion"
Pr. 175 "user group 2 registration"
Pr. 176 "user group 2 deletion"
•
Pr. 160 "user group read selection" is used to limit the parameters which may be read.
•
From among all parameters, a total of 32 parameters can be registered to two different user groups.
The registered parameters may only be accessed for reading and writing.
Parameters other than those registered to the user groups cannot be read.
Parameter
Number
Factory
Setting
Setting Range
Remarks
160
9999
0, 1, 10, 11, 9999
173
0
0 to 999
174
0
0 to 999, 9999
9999: Batch deletion
175
0
0 to 999
176
0
0 to 999, 9999
9999: Batch deletion
<Examples of use>
(1) Parameter registration to user group (when registering Pr. 3 to user group 1)
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
Pr. 173 reading
SET
SET
The number of parameters
registered for user setting
appears.
Using the key,
choose the parameter
number to be registered.
Pr. 3 is registered to user
group 1.
Using the key,
move to the next parameter
to be registered.
Using the key, make
registration.
.....
Flickering
.....
.....
.....
1.5 s
SET
(2) Parameter deletion from user group (when deleting Pr. 5 from user group 1)
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
Pr. 174 reading
SET
SET
1.5 s
The number of parameters
registered for user setting
appears.
Using the key,
choose the parameter
number to be deleted.
Pr. 5 is deleted from user
group 1.
Using the key,
choose the parameter to be
deleted.
Using the key, make
deletion.
..
...
Flickering
..
...
..
...
..
...
SET
(3) By setting the required value in Pr. 160, make the user groups valid or invalid.
Pr. 160 Setting
Description
0
All parameters can be accessed for reading and writing.
1
Parameters registered to user group 1 may only be accessed for reading and writing.
10
Parameters registered to user group 2 may only be accessed for reading and writing.
11
Parameters registered to user groups 1 and 2 may only be accessed for reading and writing.
9999
Simple mode parameters may only be accessed for reading and writing. For more information, refer
to page 54.
4
Summary of Contents for FR-F500 Series
Page 221: ......