184
z
Dedicated motor (SF-V5RU(H)) outline dimension drawings (standard horizontal type with brake)
Dimensions table
(Unit: mm)
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3. The size difference of top and bottom of the shaft center height is
4. The 400V class motor has -H at the end of its type name.
5. Since a brake power device is a stand-alone, install it inside the enclosure.
(This device should be arranged at the customer side.)
Frame Number 112M, 132S, 132M
SF-V5RU(H) , ,
Frame Number 160M, 160L, 180M, 180L
SF-V5RU(H) , , ,
Frame Number 200L
SF-V5RU(H) , ,
SF-V5RU
K
SF-V5RU
K1
SF-V5RU
K3
SF-V5RU
K4
Frame
No.
Mass
(kg)
Motor
Shaft End
Terminal Screw Size
A
B
C
D
E
F
G
H
I
J
KA KD KG KL KP
L
M ML
N
X
XB
Z
Q QK
R
S
T
U
W U,V,W A,B,(C) G1,G2 B1,B2
3
—
—
—
112M
53
355 135 112 228 95
70 6.5 —
—
40
69
27
93 242 290 555 230 242 180
4
70
12
60
45 200 28j6 7
4
8
M6 M4 M4 M4
5
3
—
—
132S
70
416 152 132 266 108 70 6.5 —
—
40
75
27 117 256 329 655 256 268 180
4
89
12
80
63 239 38k6 8
5
10 M6 M4 M4 M4
7
5
3
—
132M
80
435 171 132 266 108 89 6.5 —
—
40
94
27 117 256 329 693 256 268 218
4
89
12
80
63 258 38k6 8
5
10 M6 M4 M4 M4
11
7
5
—
160M
140 522.5 198 160 318 127 105
8
—
—
50 105 56 115 330 391 845.5 310 — 254
4
108 14.5 110 90 323 42k6 8
5
12 M8 M4 M4 M4
15
11
7
3
160L
155 544.5 220 160 318 127 127
8
—
—
50 127 56 115 330 391 889.5 310 — 298
4
108 14.5 110 90 345 42k6 8
5
12 M8 M4 M4 M4
18
—
—
—
180M
185
568.5 225.5 180 363 139.5 120.5 8
—
—
50 127 56 139 352 428 920 335 — 285
4
121 14.5 110 90 351.5 48k6 9
5.5 14 M8 M4 M4 M4
22
15
11
—
215
—
18
15
5
180L
255 587.5 242.5 180 363 139.5 139.5 8
—
—
50 146 56 139 352 428 958 335 — 323
4
121 14.5 110 90 370.5 55m6 10
6
16 M8 M4 M4 M4
30
—
—
7
200L
305
644.5 267.5 200 406 159 152.5 11
—
—
70 145 90 487 — 546 1070 390 — 361
4
133 18.5 140 110 425.5 60m6 11
7
18 M10 M4 M4 M4
37, 45
22, 30
18, 22
—
330
—
37
30
11, 15
225S
395 659 277 225 446 178 143 11
—
—
70 145 90 533 — 592 1091 428 — 342
4
149 18.5 140 110 432 65m6 11
7
18 M10 M4 M4 M4
3KB
5KB 7KB
Connector (for encoder)
MS3102A20-29P
Earth (ground)
terminal (M5)
Mark for earthing
(grounding)
Suction
Exhaust
Direction of
cooling fan wind
A
A
R
N
F
F
XB
C
G
D
ML
M
E
E
J
B
Q
QK
Main
terminal box
A
L
Terminal box for cooling fan
φ
22
φ
27
KA
KL
KP
H
KG
Section AA
W
S
U
T
Sliding distance
Frame leg viewed
from above
Z
X
1
2
1
2
V
U
B2
B1
W
G1 G2
C
B
A
For motor (U, V, W)
For cooling fan (A, B)
For brake (B1, B2)
For thermal protector (G1, G2)
Earthing (grounding)
terminal (M4)
Main terminal box
Earthing (grounding)
terminal (M4)
Terminal box for cooling fan
11KB 15KB 18KB 22KB
30KB 37KB 45KB
Sliding distance
Frame leg viewed
from above
X
Z
W
S
U
T
Section AA
Connector (for encoder)
MS3102A20-29P
Earth (ground)
terminal (M8)
Mark for earthing
(grounding)
Suction
Direction of
cooling fan wind
Terminal box for cooling fan
1, 2
1
2
A
A
R
B
110
KA
Exhaust
90
N
F
F
XB
L
A
H
C
G
D
M
E
E
J
KG
φ
56
φ
22
KL
KP
Main
terminal box
Sliding distance
Z
X
Frame leg viewed
from above
Section AA
U
T
W
S
Connector (for encoder)
MS3102A20-29P
Earth (ground)
terminal (M12)
Mark for earthing
(grounding)
1
2
D
H
C
G
M
E
E
J
φ
90
KP
KG
A
A
R
B
140
KA
110
N
F
F
XB
Suction
Exhaust
Direction of
cooling fan wind
L
A
Terminal box for cooling fan
1, 2
φ
22
Main
terminal box
B2
B1
U
G2
G1
W
V
C
B
A
For cooling fan (A, B, C)
For motor (U, V, W)
Earthing
(grounding)
terminal (M8)
Earthing (grounding)
terminal (M4)
For brake (B1, B2)
For thermal protector (G1, G2)
Main terminal box
Terminal box for cooling fan
indicates an inserting position of a bolt with hex
head holes for manual opening.
Make sure to earth the earth terminal of the frame
installation foot as well as the earth terminal in the
terminal box.
0
-0.5
Summary of Contents for FR-A741-11K
Page 7: ...MEMO ...
Page 216: ...209 MEMO ...