183
7.3.2
Dedicated motor outline dimension drawings
z
Dedicated motor (SF-V5RU(H)) outline dimension drawings (standard horizontal type)
Dimensions table
(Unit: mm)
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3 The size difference of top and bottom of the shaft center height is
4 The 400V class motor has -H at the end of its type name.
Frame Number 112M, 132S, 132M
SF-V5RU(H) , ,
Frame Number 160M, 160L, 180M, 180L
SF-V5RU(H) , , ,
Frame Number 200L
SF-V5RU(H) , ,
SF-V5RU
K
SF-V5RU
K1
SF-V5RU
K3
SF-V5RU
K4
Frame
No.
Mass
(kg)
Motor
Terminal Screw Size
A
B
C
D
E
F
H
I
KA
KG KL(KP)
L
M
ML
N
XB
Q
QK
R
S
T
U
W
U,V,W A,B,(C) G1,G2
3
—
—
—
112M
41
278 135
112
228
95
70
226 253
69
93
242
478 230 242 180
70
60
45
200 28j6
7
4
8
M6
M4
M4
5
3
—
—
132S
52
303 152 132 266 108
70
265 288
75
117
256
542 256 268 180
89
80
63
239 38k6
8
5
10
M6
M4
M4
7
5
3
—
132M
62
322 171 132 266 108
89
265 288
94
117
256
580 256 268 218
89
80
63
258 38k6
8
5
10
M6
M4
M4
11
7
5
—
160M
99
412 198 160 318 127 105 316 367 105
115
330
735 310
—
254 108
—
—
323 42k6
8
5
12
M8
M4
M4
15
11
7
3
160L
113
434 220 160 318 127 127 316 367 127
115
330
779 310
—
298 108
—
—
345 42k6
8
5
12
M8
M4
M4
18
—
—
—
180M
138
438.5 225.5 180 363 139.5 120.5 359 410 127 139
352
790 335
—
285 121
—
—
351.5 48k6
9
5.5
14
M8
M4
M4
22
15
11
—
160
—
18
15
5
180L
200
457.5 242.5 180 363 139.5 139.5 359 410 146 139
352
828 335
—
323 121
—
—
370.5 55m6
10
6
16
M8
M4
M4
30
—
—
7
200L
238
483.5 267.5 200 406 159 152.5 401
—
145 487
(546)
909 390
—
361 133
—
—
425.5 60m6
—
—
—
M10
M4
M4
37, 45
22, 30
18, 22
—
255
—
37
30
11, 15
225S
320
500 277 225 446 178 143 446
—
145 533
(592)
932 428
—
342 149
—
—
432 65m6
—
—
—
M10
M4
M4
3K
5K
7K
4
12
Sliding distance
Frame leg viewed
from above
S
U
T
W
Section AA
Mark for earthing
(grounding)
Earth (ground) terminal (M5)
φ
27
40
E
E
M
ML
6.5
C
H
I
KG
D
KL
Connector (for encoder)
MS3102A20-29P
Direction of
cooling fan wind
Exhaust
Suction
XB
F
F
N
QK
KA
Q
B
A
R
L
A
A
For motor (U, V, W)
For cooling fan (A, B)
Thermal protector (G1, G2)
A
B
G2
G1
U
V
W
Earthing (grounding) terminal (M4)
11K 15K 18K 22K
30K 37K 45K
Direction of
cooling fan
wind
Mark for earthing
(grounding)
Earth (ground)
terminal (M8)
With guard
wires
Exhaust
Suction
Connector (for encoder)
MS3102A20-29P
φ
56
KG
XB
F
F
N
90
KA
110
B
A
R
L
50
E
E
M
D
KL
8
C
H
I
A
A
Section AA
T
U
S
W
14.5
4
Sliding distance
Frame leg viewed
from above
Frame leg viewed
from above
4
18.5
Sliding distance
S
W
T
U
Section AA
Connector (for encoder)
MS3102A20-29P
Mark for earthing
(grounding)
Earth (ground)
terminal (M12)
With guard
wires
KG
KP
L
A
Direction of
cooling fan
wind
Exhaust
Suction
φ
90
70
E
E
M
11
C
H
D
XB
F
F
N
110
KA
140
B
R
A
A
For motor (U, V, W)
For cooling fan (A, B, C)
For thermal protector (G1, G2)
Earthing (grounding)
terminal (M8)
Make sure to earth the earth terminal of the frame installation foot
as well as the earth terminal in the terminal box.
0
-0.5