185
z
Dedicated motor (SF-V5RU(H)) outline dimension drawings (flange type)
Dimensions table
(Unit: mm)
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
For use under the shaft, the protection structure of the cooling fan is IP20.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3. The size difference of top and bottom of the shaft center height is
4 The 400V class motor has -H at the end of its type name.
Frame Number 112M, 132S, 132M
SF-V5RUF(H) , ,
Frame Number 160M, 160L, 180M, 180L
SF-V5RUF(H) , , ,
Frame Number 200L
SF-V5RUF(H) , ,
SF-V5RU
K
SF-V5RU
K1
SF-V5RU
K3
SF-V5RU
K4
Flange
Number
Frame
No.
Mass
(kg)
Motor
Shaft End
Terminal Screw Size
D
IE
KB
KD
KL
LA
LB
LC
LE
LG
LL
LN
LZ
LR
Q
QK
S
T
U
W
U,V,W A,B,(C) G1,G2
3
—
—
—
FF215 112M
46
228
141
239
27
242
215 180j6 250
4
16
448
4
14.5
60
60
45
28j6
7
4
8
M6
M4
M4
5
3
—
—
FF265 132S
65
266
156
256
27
256
265 230j6 300
4
20
484
4
14.5
80
80
63
38k6
8
5
10
M6
M4
M4
7
5
3
—
FF265 132M
70
266
156
294
27
256
265 230j6 300
4
20
522
4
14.5
80
80
63
38k6
8
5
10
M6
M4
M4
11
7
5
—
FF300 160M
110
318
207
318
56
330
300 250j6 350
5
20
625
4
18.5
110
110
90
42k6
8
5
12
M8
M4
M4
15
11
7
3
FF300 160L
125
318
207
362
56
330
300 250j6 350
5
20
669
4
18.5
110
110
90
42k6
8
5
12
M8
M4
M4
18
—
—
—
FF350 180M
160
363
230 378.5
56
352
350 300j6 400
5
20
690
4
18.5
110
110
90
48k6
9
5.5
14
M8
M4
M4
22
15
11
—
185
—
18
15
5
FF350 180L
225
363
230 416.5
56
352
350 300j6 400
5
20
728
4
18.5
110
110
90
55m6
10
6
16
M8
M4
M4
30
—
—
7
FF400 200L
270
406
255
485
90
346
400 350j6 450
5
22
823.5
8
18.5
140
140
110 60m6
11
7
18
M10
M4
M4
37, 45
22, 30
18, 22
—
290
3K
5K
7K
Section BB
W
U
T
S
LN LZ
KD
KL
IE
A
A
LA
Connector (for encoder)
MS3102A20-29P
Earth (ground) terminal (M5)
Mark for earthing (grounding)
LL
KB
LR
LG
LE
QK
Q
LC
LB
Section
AA
B
B
D
Suction
Direction of
cooling fan wind
Exhaust
For motor (U, V, W)
For cooling fan (A, B)
For thermal protector (G1, G2)
A
B
G2
G1
U
V
W
Earthing (grounding)
terminal (M4)
11K 15K 18K 22K
30K 37K 45K
Section BB
W
S
T
U
A
A
LN LZ
LA
IE
KL
KD
QK
Q
Connector (for encoder)
MS3102A20-29P
Earth (ground) terminal (M8)
Mark for earthing (grounding)
With guard wires
Section
AA
LC
LB
B
B
LR
KB
LG
LE
LL
D
Suction
Direction of
cooling fan wind
Exhaust
Section BB
W
S
T
U
LR
Q
QK
Connector (for encoder)
MS3102A20-29P
Earth (ground) terminal (M12)
Mark for earthing (grounding)
With guard wires
Section
AA
LC
LB
B
B
KB
LG
LE
LL
D
Suction
Direction of
cooling fan wind
Exhaust
A
A
LN LZ
LA
IE
KL
KD
For motor (U, V, W)
For cooling fan (A, B, C)
For thermal protector (G1, G2)
Earthing (grounding)
terminal (M8)
Make sure to earth the earth terminal of the flange section
as well as the earth terminal in the terminal box.
0
-0.5
Summary of Contents for FR-A741-11K
Page 7: ...MEMO ...
Page 216: ...209 MEMO ...