10
PARAMETER LIST
733
Taper setting analog input selection
3 to 6, 9999
1
9999
734
Dancer tension setting input selection
3 to 6, 9999
1
9999
737
Stall torque setting
0 to 200%
0.1%
20%
738
Speed limit for stall operation
0 to 60Hz
0.01Hz
1Hz
739
Mechanical loss setting frequency bias
400 to 600%
1%
500%
740
Mechanical loss setting frequency 1
0 to 400Hz, 9999
0.01Hz
9999
741
Mechanical loss 1
400 to 600%
1%
500%
742
Mechanical loss setting frequency 2
0 to 400Hz, 9999
0.01Hz
9999
743
Mechanical loss 2
400 to 600%
1%
500%
744
Mechanical loss setting frequency 3
0 to 400Hz, 9999
0.01Hz
9999
745
Mechanical loss 3
400 to 600%
1%
500%
746
Mechanical loss setting frequency 4
0 to 400Hz, 9999
0.01Hz
9999
747
Mechanical loss 4
400 to 600%
1%
500%
748
Mechanical loss setting frequency 5
0 to 400Hz, 9999
0.01Hz
9999
749
Mechanical loss 5
400 to 600%
1%
500%
750
Target winding diameter
1 to 6553mm
1mm
1mm
751
Dancer input offset
400 to 600%
0.01%
500%
752
Material thickness d1
0 to 20mm, 9999
0.001mm
9999
753
Material thickness d2
0 to 20mm
0.001mm
1mm
754
Material thickness d3
0 to 20mm
0.001mm
1mm
755
Material thickness d4
0 to 20mm
0.001mm
1mm
756
First acceleration time for main speed
0 to 3600s/360s
0.1s/0.01s
15s
757
First deceleration time for main speed
0 to 3600s/360s
0.1s/0.01s
15s
758
Second acceleration time for main
speed
0 to 3600s/360s
0.1s/0.01s
15s
759
Second deceleration time for main
speed
0 to 3600s/360s
0.1s/0.01s
15s
760
Third acceleration time for main speed
0 to 3600s/360s
0.1s/0.01s
15s
,
761
Third deceleration time for main speed
0 to 3600s/360s
0.1s/0.01s
15s
762
Winding/unwinding selection
0, 1
1
0
,
763
Line speed input selection
0 to 7
1
0
764
Pulse reference for line speed input
0.01 to 200
0.01kpps
30kpps
765
Voltage reference for line speed input
0.1 to 100%
0.1%
50%
766
Line speed reference
1 to 6553.4
0.1
1000
,
767
Line speed unit
0, 1, 2, 3
1
0
,
768
Line speed input filter time constant
0 to 5s
0.001s
0.025s
769
Filter treatment waiting time
0 to 100s
0.01s
0s
770
Filter time constant
0 to 100s
0.01s
0s
771
r-r' limit value (diameter)
0 to 9.998, 9999
0.001mm
1mm
772
r-r' limit disable time
0 to 100s
0.01s
0s
773
Gear ratio numerator (driver side)
1 to 65534
1
1
774
Gear ratio denominator (follower side)
1 to 65534
1
1
775
Speed control proportion term applied
diameter 1
1 to 99%, 9999
1%
9999
776
Speed control proportion term applied
diameter 2
1 to 99%, 9999
1%
9999
777
Speed control proportional gain 1
0 to 1000%, 9999
1%
9999
778
Speed control proportional gain 2
0 to 1000%, 9999
1%
9999
779
Speed control proportional gain 3
0 to 1000%, 9999
1%
9999
780
Speed control proportional gain 4
0 to 1000%, 9999
1%
9999
781
Winding diameter storage selection
0, 1
1
0
782
Stored winding diameter
1 to 6553
1mm
1mm
783
Operation time with stored winding
diameter
0 to 100s
0.01s
0s
785
Terminal 4 function setting
1, 2, 9999
1
9999
,
786
Number of averaging for winding
diameter calculation
0 to 10
1
4
787
Taper ratio setting
0 to 100%, 9999
0.1%
0%
,
788
Winding diameter at taper start
1 to 6553mm, 9999
1mm
9999
,
789
Dancer tension setting
1 to 100, 9999
0.1
100.0
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page