51
Dedicated monitor function
3.10.6 Analog output signal for dancer tension setting (Pr. 718, Pr. 719, Pr. 733, Pr. 734,
Pr. 785, Pr. 787 to Pr. 789)
Dancer is controlled with an air cylinder. Set an analog signal, which is output for tension setting to control the air cylinder,
with terminal FM/AM.
Set
Pr. 785 Terminal 4 function setting
and
Pr. 733 Taper setting analog input selection
to use the taper setting analog input signal
with an analog input terminal.
(1) Control diagram
(2) Connection example
When potentiometer is input
(3) Tension output command setting
To output tension commands from an inverter, set the AM and FM output terminals as follows.
Use
Pr. 900
to calibrate the terminal FM, and
Pr. 901
for the terminal AM.
Parameter
Number
Name
Setting Range
Increments
Initial
Value
Remarks
718
Dancer tension setting bias
0 to 200%
0.1%
0%
719
Dancer tension setting gain
0 to 200%
0.1%
100%
733
Taper setting analog input
selection
3 to 6, 9999
1
9999
3: terminal 2
4: terminal 4
5: terminal 1
6: terminal 6 (FR-A7AZ)
9999:disabled
734
Dancer tension setting input
selection
785
Terminal 4 function setting
1, 2, 9999
1
9999
1: compensation input
2: analog input signal for taper setting
9999:terminal 4 is disabled
787
Taper ratio setting
0 to 100%, 9999
0.1%
0%
9999:input from the analog terminal
assigned by
Pr. 733
.
788
Winding diameter at taper
start
1 to 6553mm,
9999
1mm
9999
9999:taper start at minimum winding
diameter
789
Dancer tension setting
1 to 100, 9999
0.1
100
9999:input from the analog terminal
assigned by
Pr. 734
.
Signal Type
Minimum
Increment
Parameter Setting
Pr.52
Pr.54
Pr.158
DU LED
PU main
monitor
Terminal FM
Terminal AM
Dancer tension command
1%
39
39
39
39
Dancer tension command 2
1%
46
46
46
46
100 (Max. winding diameter -
Pr. 788
)
Pr. 787 9999
Pr. 787
= "9999"
Pr. 789
= "9999"
T
Pr. 718
Pr. 719
Taper setting
(r -
Pr. 788
)
T
+
-
FM
AM
Pr. 54
= "39"
Pr. 54
= "46"
Pr. 15
= "46"
Pr. 158
=
"39"
X83
Analog output signal for dancer tension setting
Analog terminal input
(calibrated)
Pr. 733
Pr. 787
Dancer tension
setting
Pr. 789
Analog terminal
input
Pr. 734
Dancer tension setting
Bias
Gain
Pr. 789
"9999"
Pr. 900
Pr. 901
r
Pr. 788
r <
Pr. 788
FR-A700-A1
2 (0 to 10V)
Main speed
1 ( 10V)
Dancer signal
10E
Tension setting
AM
5
Taper ratio setting
Use 1/2W1k
Ω.
When frequently
set, use 2W1k
Ω.
Use 1/2W1k
Ω.
When frequently
set, use 2W1k
Ω.
4
5
To an electro-pneumatic
converter
Pr. 733
=
"4"
Pr. 785
=
"2"
Pr. 787
=
"9999"
Pr. 158
=
"39"