5
PARAMETER LIST
144
Speed setting switchover
0, 2, 4, 6, 8, 10, 102, 104,
106, 108, 110
1
4
—
145
PU display language selection
0 to 7
1
0
—
148
Stall prevention level at 0V input
0 to 220%
0.1%
150%
—
149
Stall prevention level at 10V input
0 to 220%
0.1%
200%
—
150
Output current detection level
0 to 220%
0.1%
150%
—
151
Output current detection signal delay
time
0 to 10s
0.1s
0s
—
152
Zero current detection level
0 to 220%
0.1%
5%
—
153
Zero current detection time
0 to 1s
0.01s
0.5s
—
154
Voltage reduction selection during stall
prevention operation
0, 1
1
1
—
155
RT signal function validity condition
selection
0, 10
1
0
—
156
Stall prevention operation selection
0 to 31, 100, 101
1
0
—
157
OL signal output timer
0 to 25s, 9999
0.1s
0s
—
158
AM terminal function selection
1 to 3, 5 to 14, 17, 18, 21,
24, 32 to 34, 39 to 44, 46
1
1
160
User group read selection
0, 1, 9999
1
0
—
161
Frequency setting/key lock operation
selection
0, 1, 10, 11
1
0
—
162
Automatic restart after instantaneous
power failure selection
0, 1, 2, 10, 11, 12
1
0
—
165
Stall prevention operation level for
restart
0 to 220%
0.1%
150%
—
166
Output current detection signal
retention time
0 to 10s, 9999
0.1s
0.1s
—
167
Output current detection operation
selection
0, 1
1
0
—
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
0, 10, 9999
1
9999
—
171
Operation hour meter clear
0, 9999
1
9999
—
172
User group registered display/batch
clear
9999, (0 to 16)
1
0
—
173
User group registration
0 to 999, 9999
1
9999
—
174
User group clear
0 to 999, 9999
1
9999
—
178
STF terminal function selection
0 to 14, 16 to 18, 20,
22 to 28, 30, 32 to 35,
42 to 44, 51 to 60, 62,
64 to 67, 70, 71, 83 to 93,
9999
1
60
179
STR terminal function selection
0 to 14, 16 to 18, 20,
23 to 28, 30, 32 to 35,
42 to 44, 51 to 59, 61, 62,
64 to 67, 70, 71, 83 to 93,
9999
1
61
180
RL terminal function selection
0 to 14, 16 to 18, 20,
23 to 28, 30, 32 to 35,
42 to 44, 51 to 59, 62,
64 to 67, 70, 71, 83 to 93,
9999
1
0
181
RM terminal function selection
1
1
182
RH terminal function selection
1
2
183
RT terminal function selection
1
3
184
AU terminal function selection
0 to 14, 16 to 18, 20,
23 to 28, 30, 32 to 35,
42 to 44, 51 to 59, 62 to 67,
70, 71, 74, 83 to 93, 9999
1
4
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting