18
Dedicated I/O signal
3.4.3
Analog input signals and pulse train input signals
Function
Analog input
Single-phase pulse
train input
Encoder
pulse train
input
Refer to
page
Terminal 1
Pr. 868
Terminal 2
Terminal 4
Pr. 785
Terminal 6
(FR-A7AZ)
Pr. 406
Terminal
JOG
Pr. 291
FR-A7AL
FR-A7AP/
FR-A7AL
Frequency (speed)
command
1
0
1, 11, 21,
100
Refer to the
Instruction
Manual
(Applied) of
FR-A700 series
Frequency setting
auxiliary
0
1
Override
1
Magnetic flux command
1
Regenerative torque limit
2
2
Torque command
3, 4
3, 4
Stall prevention operation
level
4
4
Torque limit
4
4
Forward/reverse rotation
speed limit
5
5
Torque bias
6
6
: Setting available,
: Setting not available
Function
Analog input
Single-phase pulse
train input
Encoder
pulse train
input
Refer to
page
Terminal 1 Terminal 2 Terminal 4
Terminal 6
FR-A7AZ
Terminal
JOG
FR-A7AL
FR-A7AP/
FR-A7AL
Dancer signal input selec-
tion
Pr. 731
5
3
4
6
Dancer main speed com-
mand input selection
Pr. 732
5
3
4
6
1
7
2
Line speed input selection
Pr. 763
5
3
4
6
1
7
2
Taper setting analog input
selection
Pr. 733
5
3
4
6
,
Dancer tension setting input
selection
Pr. 734
5
3
4
6
*1
Can be set when
Pr. 291
= "1, 11, 21, or 100".
*2
Setting
Pr. 785
= "2" sets the taper ratio setting as the terminal 4 input regardless the
Pr. 733
setting.
: Setting not available
REMARKS
• While the dancer/tension control selection X83 signal is ON, the setting values of
Pr. 731 to Pr. 734
and
Pr. 763
have higher precedence
over the other assigned terminal settings such as
Pr. 868
,
Pr. 785
= "1", and
Pr. 406
. (Example: When
Pr. 731
= "5" and
Pr. 868
= "0", the
terminal 1 is set to the dancer signal input.)
• For the taper setting analog input, the setting of
Pr. 785
Terminal 4 function setting
has higher precedence.
• While tension control is valid (
Pr. 800
= "6 or 16"), the following parameter settings are invalid:
Pr. 731 Dancer signal input selection,
Pr. 732 Dancer main speed command input selection, and Pr. 734 Dancer tension setting input selection
.
• The dedicated-function parameters take the following precedence over each other. When several functions are assigned to a terminal,
input to the function of lower precedence is regarded as 0.
Terminal 4 function setting
(
Pr. 785
= "2") >
Pr. 731 Dancer signal input selection
>
Pr. 763 Line speed input selection
>
Pr. 732 Dancer main speed
command input selection
>
Pr. 733 Taper setting analog input selection
>
Pr. 734 Dancer tension setting input selection
.