TB1
ECB1
L
N
ECB2
L1
L2
L3
N
L1
L2
L3
<Figure 6.1>
Electrical connections 3 phase
Description
Power supply
Capacity
Breaker
Wiring
Booster heater (Primary circuit)
3~ 400 V 50 Hz
9 kW
16 A *2
2.5 mm²
Immersion heater (DHW tank) (Option)
~/N 230 V 50 Hz
1 kW
16 A *2
2.5 mm²
Ground source unit power supply
3N~ 400 V 50 Hz
Ground source unit circuit breaker capacity
*3
16 A
Wiring No. × size (mm²)
Ground source unit power supply, earth
5 × Min. 1.5
Circuit rating
Ground source unit L1-N, L2-N, L3-N
*4
230 V AC
*1. If the installed earth leakage circuit breaker does not have an over-current protection function, install a breaker with that function along the same power line.
*2. A breaker with at least 3.0 mm contact separation in each pole shall be provided.Use earth leakage breaker (NV).
The breaker shall be provided to ensure disconnection of all active phase conductors of the supply.
*3. Use wires in conformity with design 60245 IEC 57.
*4. The values given in the table above are not always measured against the ground value.
Note:
1. Wiring size must comply with the applicable local and national codes.
2. Install an earth line longer than power cables
3. Please keep enough output capacity of power supply for each heater. Insufficient power supply capacity might cause chattering.
Affix label A that is included with the manuals near each wiring diagram for heat pump units.
Earth leak
-
age circuit
breaker
*1 *2
Wiring circuit
breaker
N.F.
Isolating
switch
Power supply
3N~ 400 V 50 Hz
Power supply
3~ 400 V 50 Hz
Power supply
~/N 230 V 50 Hz
Wiring circuit
breaker or
Isolating
switch
Wiring circuit
breaker or
Isolating
switch
To control board
For
booster heater
(Primary circuit)
For
Immersion heater
(DHW tank)
(Option)
13
OCH722A
FIELD WIRING
6
Breaker abbreviation
Meaning
ECB1
Earth leakage circuit breaker for booster heater
ECB2
Earth leakage circuit breaker for immersion heater (option)
TB1
Terminal block 1