8
OCH722A
SPECIFICATIONS
2
Product specification
Model name
EHGT17D-YM9ED
Nominal domestic hot water volume
170 L
Overall unit dimensions
1750 × 595 × 680 mm (Height × Width × Depth)
Weight (empty)
181 kg
Weight (full)
360 kg
Refrigerant
R32
The amount of refrigerant
0.9kg
Water volume of heating circuit in the unit *1
5.47 kg
Brine volume of brine circuit in the unit
3.11 kg
Safety device
Water circuit
(Primary)
Control thermistor
Heating
1 to 80°C
Pressure relief valve
0.3 MPa (3bar)
Flow sensor
Min. flow 5.0 L/min
Booster heater
Manual reset thermostat
90°C
Thermal Cut-out (for dry run prevention)
121°C
DHW tank
Control thermistor
40 to 70°C
Temperature and pressure relief valve/
Pressure relief valve
1.0 MPa
(10 bar)
Brine circuit
Control thermistor
−8 to +30°C
Flow switch
Min. flow 5.5 L/min
Refrigerant
circuit
Control thermistor (High)
−20 to +125°C
Control thermistor (Low)
−40 to +90°C
Pressure switch
4.14 ± 0.1 MPa
Pressure sensor
0 to 5.0 MPa
Primary circuit circulating Pump
DC motor
Sanitary circuit circulating Pump
AC motor
Brine circuit circulating Pump
DC motor
Connections
Water
28 mm compression primary circuit/
22 mm compression DHW circuit
Brine
28 mm compression
Guaranteed
operating range
Ambient *2
0 to 35°C ( 80 %RH)
Brine inlet temperature
−8 to +30°C
Min. Brine outlet temperature
−12°C
Operating range
Heating
Room temperature
10 to 30°C
Flow temperature
20 to 60°C
DHW
40 to 60°C
Legionella prevention
60 to 70°C
Flow rate range
Primary circuit
Max.
27.7 L/min
Min.
7.1 L/min
Brine circuit
Max.
27.7 L/min
Min.
7.1 L/min
DHW tank performance
Maximum allowable hot water temperature
70°C
Electrical data
Heat pump
(exclude booster
heater)
Power supply
(Phase, voltage, frequency)
3N~, 400 V, 50 Hz
Breaker
16 A
Booster heater
Power supply
(Phase, voltage, frequency)
3~, 400 V, 50 Hz
Capacity
3 kW + 6 kW
Current
13 A
Breaker
16 A
Sound power level @B0W35 (EN12102)
42 dB(A)
<Table 2.1>
Optional extras
• Immersion heater (1Ph 1kW)
PAC-IH01V2-E
• Wireless Remote Controller
PAR-WT50R-E
• Wireless Receiver
PAR-WR51R-E
• Remote Sensor
PAC-SE41TS-E
• Thermistor
PAC-TH011-E
• High temperature thermistor
PAC-TH012HT-E
• ecodan Wi-Fi Interface
MAC-567IF-E1
• 2-zone kit
PAC-TZ02-E
• Expansion vessel(12L)
PAC-EVP12-E
*1 Volume of sanitary water circuit is not included in this value
*2 The environment must be frost-free.
Summary of Contents for EHGT17D-YM9ED