![Mitsubishi Electric CR800-D Series User Manual Download Page 182](http://html.mh-extra.com/html/mitsubishi-electric/cr800-d-series/cr800-d-series_user-manual_238858182.webp)
Dedicated input/output signals 180
<Consumption degree reset>
Parameter
name
Category
Function
Signal
level
Signal number at factory
default
CR800-R/Q
CR800-D
PMRSTGRS
Input
Consumption degree reset of predictive/preventive
maintenance (grease)
Resets the grease consumption degree information.
* The reset target axis is specified in IODATA or
DIODATA using the axis bit pattern.
−
-1,
-1,
Output
Outputs the reset completion.
−
-1
-1
PMRSTBLT
Input
Consumption degree reset of predictive/preventive
maintenance (timing belt)
Resets the timing belt consumption degree
information.
* The reset target axis is specified in IODATA or
DIODATA using the axis bit pattern.
−
-1,
-1,
Output
Outputs the reset completion.
−
-1
-1
PMRSTDEC
Input
Consumption degree reset of predictive/preventive
maintenance (decelerator)
Resets the reduction gear consumption degree
information.
* The reset target axis is specified in IODATA or
DIODATA using the axis bit pattern.
−
-1,
-1,
Output
Outputs the reset completion.
−
-1
-1
PMRSTBRG
Input
Consumption degree reset of predictive/preventive
maintenance (bearing)
Resets the bearing consumption degree
information.
* The reset target axis is specified in IODATA or
DIODATA using the axis bit pattern.
−
-1,
-1,
Output
Outputs the reset completion.
−
-1
-1
PMRSTBSS
Input
Consumption degree reset of predictive/preventive
maintenance (ball screw/ball spline)
Resets the ball screw/ball spline consumption
degree information.
* The reset target axis is specified in IODATA or
DIODATA using the axis bit pattern.
−
-1,
-1,
Output
Outputs the reset completion.
−
-1
-1
PMRSTOH
Input
Consumption degree reset of predictive/preventive
maintenance (overhaul)
Resets the consumption degree information and
operating information (integration time/accumulation
count) of all parts.
* The reset target axis is all axes.
−
-1,
-1,
Output
Outputs the reset completion.
−
-1
-1
PMRSTNEW
Input
Consumption degree reset of predictive/preventive
maintenance (replace to new robot)
Resets the consumption degree information and
operating information (integration time/accumulation
count) of all parts.
* The reset target axis is all axes.
−
-1,
-1,
Output
Outputs the reset completion.
−
-1
-1
Summary of Contents for CR800-D Series
Page 2: ......
Page 25: ...Basic specifications 23 MEMO ...
Page 31: ...Basic specifications 29 MEMO ...
Page 49: ...Startup and initial settings 47 MEMO ...
Page 57: ...Consumption degree calculation function 55 MEMO ...
Page 63: ...Operating information 61 MEMO ...
Page 91: ...Maintenance 89 MEMO ...
Page 193: ...Troubleshooting 191 ...