Before starting use 12
1.4. Maintaining the robot
This function supports maintenance and inspection so that the robot can be used for a long time without
trouble.
Efficient maintenance is supported though early detection of abnormalities or deterioration of robot
components and notification of the time of maintenance parts replacement or overhaul based on the actual
operating status of the robot. However, in order to prevent failure beforehand and ensure prolonged
service life and safety of the robot, we strongly recommend periodic maintenance and inspection be
carried out.
This chapter explains maintenance and inspection of parts that are subject to this function.
For details on robot inspection items, implementation time of periodic inspection, calculation of operating
time, and maintenance and inspection procedures, refer to "5. Maintenance and Inspection" in the
separate volume "Instruction Manual/Robot Arm Setup & Maintenance"
1.4.1. Type of maintenance and inspection
There are two types of maintenance and inspection, daily inspection and periodic inspection.
The following table shows the type of maintenance and inspection.
Type of maintenance and inspection
No.
Type of inspection and
maintenance works
Description
Operating
time
(Note1)
1
Daily inspection
Inspection works to be performed every day
before starting operation for the safe use of the
robot.
2
Periodic
inspection
Monthly
inspection
Inspection and maintenance works to be
performed every month.
Every 300 hr
3
6-month
inspection
Inspection and maintenance works to be
performed every 6 months.
Every 1,800 hr
4
2-year
inspection
Inspection and maintenance works to be
performed every 2 years.
Every 7,200 hr
5
Battery
replacement
Replacement of the backup battery of the robot.
Replace the battery every year regardless of the
operating hours.
6
Lubrication
Lubrication of each axis of the robot.
Refer to "1.4.3 Lubrication" for the lubrication
schedule.
Note 1) Robot operating hours are based on 15 hours/day, 20 days/month. If the robot operates 8
hours/day, the operation hours per month are about half the above condition. Therefore,
monthly inspection shall be performed once every two months.
Summary of Contents for CR800-D Series
Page 2: ......
Page 25: ...Basic specifications 23 MEMO ...
Page 31: ...Basic specifications 29 MEMO ...
Page 49: ...Startup and initial settings 47 MEMO ...
Page 57: ...Consumption degree calculation function 55 MEMO ...
Page 63: ...Operating information 61 MEMO ...
Page 91: ...Maintenance 89 MEMO ...
Page 193: ...Troubleshooting 191 ...