GX Configurator-QP
(SW
�
D5C-QD75P-E)
Example of reading a file created with GX Configurator-AP.
GX Configurator-AP Version 1 Operating Manual
IB-66716
IB-66715
A1SD75P1-S3/P2-S3/P3-S3, AD75P1-S3/P2-S3/P3-S3 Positioning Module
User's Manual (Details)
A1SD75M1/M2/M3, AD75M1/M2/75M Positioning Module User's Manual (Details)
Title
Manual No.
IB-66900
Type QD75P/QD75D Positioning Module User's Manual (Details)
Title
Manual No.
SH-080058
Type QD75M Positioning Module User's Manual (Details)
IB-0300062
Type QD75MH Positioning Module User's Manual (Details)
IB-0300117
GX Configurator-QP Version 2 Operating Manual
SH-080172
Write to module/read from module/verify module data
Write to Flash ROM
Parameters
Buffer memory
Servo parameters
Positioning data
Block start data
Parameters
Flash ROM
Servo parameters
Positioning data
Block start data
Step 3
Read the AD75 file using "GX Configurator-QP".
Step 5
Write all positioning parameters and data, including modified data, to the "QD75 using GX Configurator-QP".
Step 4
Specify item(s) that need to be changed in "GX Configurator-QP".
Via QCPU, Q Series compatible serial
communication module, or
MELSECNET/H network remote I/O
module*
*Only when directly connected to the
remote I/O module.
• To use GX Configurator-AP data in GX Configurator-QP, it is necessary to save the file in a format that can
be read by GX Configurator-QP. Files saved in GX Configurator-AP format cannot be read by GX
Configurator-QP.
• Due
to specification differences between the AD75 and QD75, some positioning parameters may require
setting changes. Refer to the related manuals for details on the modifications. Note that positioning data
does not require any modifications.
• R
elated manuals
(a) AD75
(b) QD75
Tip
161
8.1 Replace AD75(P/M) with QD75(P/D/M/MH) while utilizing existing positioning parameters and data
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com