Signal name
Connector
terminal
number
Terminal
block side
terminal number
Phase A pulse input 24 V
A20
10
Phase A pulse input 12 V
B20
0
Phase A pulse input 5 V
A19
11
ABCOM
B19
1
Phase B pulse input 24 V
A18
12
Phase B pulse input 12 V
B18
2
Phase B pulse input 5 V
A17
13
CH2
Preset input 24 V
B17
3
Preset input 12 V
A16
14
Preset input 5 V
B16
4
CTRLCOM
A15
15
Function start input 24 V
B15
5
Function start input 12 V
A14
16
Function start input 5 V
B14
6
EQU 1
(Coincidence output point No.1)
A06
1E
EQU 2
(Coincidence output point No.2)
B06
E
A13
17
B13
7
A12
18
B12
8
A11
19
B11
9
A10
1A
B10
A
A09
1B
B09
B
A08
1C
B08
C
A07
1D
B07
D
A05
1F
B05
F
12/24 V
B02
B01
24 V
0 V
A02
A01
0 V
Phase A pulse input 24 V
Phase A pulse input 12 V
Phase A pulse input 5 V
ABCOM
Phase B pulse input 24 V
Phase B pulse input 12 V
Phase B pulse input 5 V
Preset input 24 V
Preset input 12 V
Preset input 5 V
CTRLCOM
Function start input 24 V
Function start input 12 V
Function start input 5 V
EQU 1
(Coincidence output point No.1)
EQU 2
(Coincidence output point No.2)
CH1
QD62-H01
DEC.
FUNC.
CH1 CH2
FUSE
øA
øB
QD62-H01
Cable
AC05TB
AC10TB
AC20TB
AC30TB
AC50TB
AC80TB
AC100TB
Connector/terminal block
converter module
A6TBXY36
(b) Replacement using a connector/terminal block converter module
This replacement method is suitable when the Q Series large type base unit and conversion adapter
manufactured by Mitsubishi Electric Engineering Co., Ltd. cannot be used due to system configuration and
installation location restrictions.
Connect the input/output wires, which include solderless terminals, from the existing module to the
connector/terminal block converter module using a dedicated cable. This connection is not restricted by
differences in wiring size.
The following shows the wiring configuration when using a connector/terminal block converter module.
• The input filtering system and counting speed of replacement Q Series dedicated modules QD62-H01 and
QD62-H02 are the same as those of existing A (Large Type) high-speed counter modules AD61 and
AD61S1.
High-speed counter modules can be replaced without being restrained by the specifications of existing pulse
generators (e.g. an encoder).
• AD61/AD61S1 and QD62-H01/QD62-H02 have different counting ranges.
Modify the program in order to use the same counting range as that of the module before replacement.
• AD61, AD61S1:
0 to 16,777,215 (24-bit unsigned binary)
• QD62-H01, QD62-H02: -2,147,483,648 to 2,147,483,647 (32-bit signed binary)
• The number of points occupied by the module changes from 32 to16 points, and thus the I/O signal
assignment (X/Y) also changes. Due to additional functions, the buffer memory addresses are changed and
program modification is necessary. Check the specification at "High-Speed Counter Module User's Manual":
SH-080036, and modify the program.
Tip
112
5.1 Replace high-speed counter modules (AD61(S1)) with Q Series modules