GUIDE TO INSTALLATION AND OPERATION
20
| XVP-3901
Icon #7 – Health Monitoring
(green)
Hardware OK
(red)
Hardware Health Monitoring (Fan1, Fan2, Hardware fault detected)
If this icon appears red, return the card to Miranda and specify the error code.
Section 2.
The left portion of the window contains all the parameter groups, which become highlighted when they are
selected; the main panel (4) then displays the group’s set of parameters. Each of the groups is described in detail
below.
Section 3.
The lower left corner of the window identifies the Preset currently in use, or “Custom” if none is applicable.
Section 4.
The main panel contains all the parameters specific to the group selected. It may contain several tabs to
help manage the different parameters.
Each of the panels associated with the groups accessed from the buttons in Section 2, and shown in Section 4, is
described individually in the following sections.
5.2 Video Input/Output panel
This panel allows input selection, second input operation
mode selection, and control of the deglitcher and freeze
functions.
Input Select
: choose one of the two inputs connected to
the rear panel.
•
Input 1&2 assignments are done in the Input/Output
Config Tab below.
•
Note that the XVP will switch the inputs on the
switch line only when using this control and not while
using the Input Config controls.
•
The video input status in the top section (icon #2
and #3) refers only to the inputs selected here.
Figure 5.2
Video Input/Output panel