GUIDE TO INSTALLATION AND OPERATION
XVP-3901 |
111
5.17.6 XVP Full Upgrade option (XVP-3901-UG-xx2XVP):
This option can be used to upgrade an XVP-3901-UC, -FS, -DC, or -XC model to a full XVP-3901.
•
The option name varies depending on which model you have –
xx
in the upgrade option name is the current
model designation. For example, the option to upgrade an XVP-3901-XC to a full XVP-3901 will appear as
XVP-3901-UG-XC2XVP
•
The tab for this option does not appear in this group when the card is a full XVP-3901 (as shown in the figures
above).
5.18 Alarm Config panel
This panel allows the alarm reporting of the XVP-3901 to be configured. The panel opens in a new window when the
button is clicked, and can be resized if needed.
The panel is organized in columns.
Status/Name
This contains an expandable tree listing all the alarms reported by this XVP-3901 card.
•
Each alarm name includes an icon that shows its current status
•
Some alarms may be text-only and the alarm status is shown in the name and not by a status icon
The
Card LED
,
Overall alarm
and
GSM contribution
columns contain pulldown lists that allow the level of
contribution of each individual alarm to the alarm named in the column heading to be set.
•
If there is no arrowhead in the box, there is no pulldown and the alarm is not user-configurable